Gold Member Since 2007
Audited Supplier
Ningbo Ville Electric Co., Ltd.

Furnace Transformer, Transformer, Eaf Transformer manufacturer / supplier in China, offering Furnace Transformer for Metallurgical Electric Arc Furnace Transformer Power Supply, 15 Strand Billet Continuous Casting Machine CCM, Lvb (T) Series Oil Immersed Inverted Current Transformers and so on.

(/ )

Supplier Homepage Product Furnace Transformer Furnace Transformer for Metallurgical Electric Arc Furnace Transformer Power Supply

Furnace Transformer for Metallurgical Electric Arc Furnace Transformer Power Supply

FOB Price: US $20,000-2,000,000 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $20,000-2,000,000/ Piece
Get Latest Price
Port: Shanghai, China
Production Capacity: 10/Years
Payment Terms: L/C, T/T, D/P, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: HSSPZ-63000/33
  • Phase: Three
  • Cooling Method: Oil-immersed Type Transformer
  • Usage: Electric Arc Furnace Transformer
  • Shape of Core: Ring
  • Arc: Furnace Transformer
  • Type: Calcium Carbide Furnace Transformer
  • Reference Standard: IEC 60076
  • Load Losses at 75: 280 Kw ( 60mva 950V ) (Including LV Lead Losses
  • on-Load Tap Changer: Mr
  • Trademark: ville
  • Specification: IEC
  • HS Code: 8514901000
  • Application: Power, Electronic, Instrument, Audio
  • Core: Core-type Transformer
  • Winding Type: Multi-winding Transformer
  • Frequency Characteristics: Power Frequency
  • Brand: Ville
  • Steel: Furnace
  • Test Certification: Kema
  • No Load Losses: 52kw
  • Cooling System: Ofwf, Double Tube, 2 Coolers in Service.
  • Testing: -Routine Test According to IEC Standard
  • Transport Package: Nuke Packing; Wooden Cases
  • Origin: Ningbo China
Product Description
Electric arc furnace transformer 

Main function and characteristic
Electric furnace transformers are transformers which supply power to the electric furnaces. It can drop high voltage to the working voltage the electric furnaces need.
There are many kinds of electric furnaces,so there are many kinds of electric furnace transformers cooperating with them.Now,our company manufactures following electric furnace transformers:electric furnace transformers used in steelelectric furnaces(including on-laod,no-load and enclosed reactor) ; mineral hot furnace transformers used to smelt kinds of iron alloys,hydrosilicons,carbides,etc(single phase,three phases on-load and no-load tap changer).They are low loss and energy-saving products.Cooling methods are self-cooling, forced oil water cooling, etc.It can be designed specially according with customers' requirements.
The model of the electric furnace transformer is expressed as follows:
 
The meaning of model:
H--Steelmaking arc furnace,HJ--ladle furnace,HZ--electro-slag furnace,HC--calcium carbide furnace,HK--mineral hot furnace,HG--line frequency induction furnace;
Number of phase:D--single phase,S--three phase;
Types of cooling device :ONAN,wind cooling F,water cooling S.
The methods of oil circulation:natural circulation,forced oilcirculation P.
Tap changer:off-circuit tap changer,OLTC Z.
Enclosed attached device:changing leakage flux,enclosed reactor K.
Rated capacity:KVA. max 140MVA 
Voltage class:KV. 35KV
Furnace Transformer for Metallurgical Electric Arc Furnace Transformer Power Supply

 
Furnace Transformer for Metallurgical Electric Arc Furnace Transformer Power Supply
Furnace Transformer for Metallurgical Electric Arc Furnace Transformer Power Supply
1.1.2 TRANSFORMER DATA
General data 
Operating Voltage 33KV±3%
Frequency 50Hz±1%
Rated capacity 60 MVA
Over load power60 MVA plus 20%,30 min.
Rated primary current 1049.7 A
Insulation Level (AC/LI)85/200 kV
Vector group D/d0 with booster regulation transformer inside.
Secondary connection Delta OPEN 
System short circuit capacity at 33kV side.1100 MVA
Secondary outlet Terminals with Bus bars come out from  top cover. 8 Buss bars  by epoxy resin arranged  along with each phase with matching cite transformer sizes.
Max. Secondary current Approximate  42120 A
Secondary voltage range 950-500 V. 
 
a) Constant power 950V-822.4 V at 60 MVA
b) Constant current About 42062 A within 824V-500V
c) Short-circuit voltage 8 % (at 950V,60MVA) 
 
Type of tap changer On load tap-changer:  
 
a) Manufacturer MR,
b) Number of tapes 17 voltage steps with 18position See attached data sheet of 60 MVA EAF transformer.
c) Oil filter equipment for OLTC             yes
 
Cooling OFWF
Furnace Transformer for Metallurgical Electric Arc Furnace Transformer Power Supply

Transformer Production :




Furnace Transformer for Metallurgical Electric Arc Furnace Transformer Power Supply

PACKING AND SHIPPING:
Furnace Transformer for Metallurgical Electric Arc Furnace Transformer Power Supply
 
Send your message to this supplier
Avatar
Ms. jennifer
manager
*From:
To: Ms. jennifer
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now