Pipe Busbar, Busbar, Enclosed Busbar manufacturer / supplier in China, offering 7.2~40.5kv Full Insulated Enclosed Pipe Busbar, 1.6mva S11 Series 35kv Power Transformer with on Load Tap Changer, Lb6-110 Type Current Transformer CT and so on.

(/ )

Supplier Homepage Product Low Voltage Power distribution Power cable &cable box 7.2~40.5kv Full Insulated Enclosed Pipe Busbar

7.2~40.5kv Full Insulated Enclosed Pipe Busbar

FOB Price: Get Latest Price
Min. Order: 1 Piece
Production Capacity: 50000 Sets
Transport Package: Wooden Case
Payment Terms: L/C, T/T, D/P, Paypal, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: Pipe Type
  • Rated Fequency: 50 Hz
  • Trademark: VILLE
  • Origin: Ningbo
  • Rated Voltage: 6,10,20,35 Kv
  • Rated Current: 1000 1600 2000 2500 3150 4000 5000 a
  • Specification: IEC CE, ISO
  • HS Code: 87
Product Description
Product Features:
This product is used for the connection between bushings in low voltage side of transformer and cabinet and feeder connection between cabinet and cabinet. Each phase insulator of this product is individually sealed and fully insulated so it is free from impact of environment and it is of high reliability. The flow-guiding body is pipe type. Besides, this kind of busbar can be installed on backbone directly so wall bushing and post insulator can be omitted.

Use requirements:
Altitude: Not more than 1000m, special design needed for over 1000m
Earthquake intensity: ≤ 8 (Amount of basic earthquake acceleration: Not more than 0.2g)
Environmental temperature: -50 ~ 50 Celsius degree
Relative humidity: Daily maximum relative humidity of ≤ 95%, monthly maximum relative humidity of 90% (when 25 Celsius degree )
Pollution level: II, III, IV
Special requirements: To negotiate with clients and manufacturer


Performance parament: Detail see table


Common Specifications: Detail see table
Rated Voltage (kV)
 
Maximum operating voltage (kV) Rated frequency (Hz) Power frequency withstand voltage (kV) Lightening impulse withstand voltage (kV) Partial discharge level Dielectric loss factor tan δ
Partial discharge measurement voltage (kV) Partial discharge electric quantity (pC)
6 7.2 50 32 60 6 5 When voltage is 10kV,tanδ≤0.005(Measure Temperature 10~40 Celsius degree
10 12 50 42 75 15/10 10/5
20 24 50 58 125 24/15 10/5
35 40.5 50 95 185 36/25 10/5
 
 
Common Specifications:
 
Rated current (A) Conductor specification Thermal stability current (effective value kA) Dynamic stability current (peak value kA) Temperature rise (K) Minimum phase interval (mm) Maximum span (m)
Copper conductor Aluminum conductor
1000 φ50×5 φ60×5 40 100 <40 275 8
1600 φ60×5 φ60×8 40 100 <40 275 8
2000 φ60×6 φ100×6 40 100 <40 275 8
2500 φ60×8 φ100×8 40 100 <40 275 8
3150 φ100×6 φ100×10 40 100 <40 275 8
4000 φ100×8 φ100×14 63 163 <40 275 8
5000 φ100×10 φ110×14 63 163 <40 275 8