• Assembled Shunt Capacitor Bank Outdoor Three Phase Capacitor Power Compensation
  • Assembled Shunt Capacitor Bank Outdoor Three Phase Capacitor Power Compensation
  • Assembled Shunt Capacitor Bank Outdoor Three Phase Capacitor Power Compensation
  • Assembled Shunt Capacitor Bank Outdoor Three Phase Capacitor Power Compensation
  • Assembled Shunt Capacitor Bank Outdoor Three Phase Capacitor Power Compensation

Assembled Shunt Capacitor Bank Outdoor Three Phase Capacitor Power Compensation

Type: Polystyrene-film-capacitors
Application: General Purpose, AC / Motor, Power
Packaging Type: Surface Mount
Capacitance: 3600kvar
Structure: Fixed Capacitor
Manufacturing Material: Polypropylene
Samples:
US$ 2000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2007

Suppliers with verified business licenses

Rating: 5.0/5

Basic Info.

Model NO.
BAM11-3600-1x3
Electrolyte
Air Medium
Usage
High Frequency Coupling
Tuning
Polystyrene Capacitor
Filter
Composite Paper Capacitor
Frequency
50Hz
Voltage
6~110kv
Applicable Standard
GB/Jb
Installation Site
Outdoor
Transport Package
Wooden Case
Specification
As per drawing
Trademark
VILLE
Origin
Ningbo China
HS Code
8535210000
Production Capacity
500000

Product Description

Use and Application
It's mainly used in 50Hz Frequency, 6kV, 10kV, 35kV, 66 kV and 110 kV rated voltage system of power frequency for
reactive compensation to increase the power factor, decrease the loss and improve power quality.

Standard:
GB/T11024-2001 Shunt capacitors under nominal voltage above 1kV for AC power systems
JB7112-2000 Assembled High Voltage Shunt capacitors

The meaning of type model
Example: BAM11/ √3-3600-1x3W
That means: Benzyl toluene impregnating, film dielectric, HV shunt capacitor, rated voltage is 11/√3kV; rated capacity
is 3600kVar, three phases, outdoor.

Features:
1. Anti-explosion, fire prevention, safety and reliability.
2. Simple infrastructures.
3. Easy maintenance.
4. Small floor space.
5. High commissioning rate.

Technical parameter
1 Rated frequency: 50/60Hz
2 Loss tangent: <=0.0005
3 Number of phases: Three phases or single phase.
4 Capacitance tolerance:0~+5%.
5 Running continuously under 1.1 times rated voltage.
6 Running continuously under not above 1.3 times rated current.
7.Creeping distance of outlet bushing: >=32kV/mm
8 Bushing pollution level: 1V

Service condition:
1 The capacitors can be used in door or outdoor.
2 The altitude of the site is not more than 1000m.
3 Temperature range: -40/55ºC.
4 There is no corrosive gas and vapor, no conductive or explosive dust, no strong mechanical vibration.
5 The remaining voltage on the terminal should not exceed 10% of rated voltage when capacitors are put into operation.
Assembled Shunt Capacitor Bank Outdoor Three Phase Capacitor Power Compensation
Assembled Shunt Capacitor Bank Outdoor Three Phase Capacitor Power Compensation
Assembled Shunt Capacitor Bank Outdoor Three Phase Capacitor Power Compensation

Assembled Shunt Capacitor Bank Outdoor Three Phase Capacitor Power Compensation

Assembled Shunt Capacitor Bank Outdoor Three Phase Capacitor Power Compensation


Our Performance:
1. Pre sale service
a. make technical solution
b. send quotation, technical data sheet and drawing
c. prepare power transmission plan, testing plan,and shipment plan
2. In sale service
a. supervise the manufacturing schedule totally in accordance with the plan
b. send photos to customer during every manufacturing process(hold point)
c. inform the customer one week before testinng.
3. After sale service
a. installation and commissioning, training the workers
b. quick response within 12 hours any time
c. provide 12 months gurantee period normally.

FAQ For You
1. Q: What is your delivery time ?
A:  Depend on the type of transformer.
2. Q: What is your payment term?
A:  30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it.
3. Q: What kind of starndard you follow?
A:  IEC, ANSI, CSA, GB, etc
4. Q: What kind of supporting documentation you can provide normally
A:  Quotation,outline drawing,manufacturing plan, quality control plan
testing plan, financial report, type test report(KEMA, CESI),reference list,etc
5. Q: What is your normal wanrranty period?
A:  12 months after transformer operation.
6. Q: Can u do installation and commissioningin user's site?
A:  Yes, we can send our installation team to user's country for service.
7. Q: Do you have any experience in this kind of transformer?
A:  Yes, we can provide reference list for check.
8. Q: Are you manufacturer or trading company?
A:  Manufacturer and Trading company.

Quality Assurance
--From the very beginning, VILLE ensures quality in every step to achieve the best quality.
 Experience Sharing
--With more than 30 years' experience in power industry, VILLE brings you an optimized solution.
 Global Service
--Wherever you are, VILLE global network will support and provide you with value.
 Quick Response
--In response to your needs without delay, VILLE  knows the value of your time.

Ville Electric Company will keep up with the century, the epoch,

Sincerely look forward to your cooperation and win-win!

Create brilliant!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2007

Suppliers with verified business licenses

Rating: 5.0/5
Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, IATF16949, ISO 14064, QC 080000, ANSI/ESD, ISO 29001, ISO 50001
Import & Export Mode
Have Own Export License
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram