• 6300kVA 10kv Three Phase Petrochemical Transformer Power Transformers for Refining and Petrochemicals
  • 6300kVA 10kv Three Phase Petrochemical Transformer Power Transformers for Refining and Petrochemicals
  • 6300kVA 10kv Three Phase Petrochemical Transformer Power Transformers for Refining and Petrochemicals
  • 6300kVA 10kv Three Phase Petrochemical Transformer Power Transformers for Refining and Petrochemicals
  • 6300kVA 10kv Three Phase Petrochemical Transformer Power Transformers for Refining and Petrochemicals
  • 6300kVA 10kv Three Phase Petrochemical Transformer Power Transformers for Refining and Petrochemicals

6300kVA 10kv Three Phase Petrochemical Transformer Power Transformers for Refining and Petrochemicals

Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio
Phase: Three
Core: Core-type Transformer
Cooling Method: Oil-immersed Type Transformer
Winding Type: Two-winding Transformer
Certification: ISO9001-2000, ISO9001
Customization:
Gold Member Since 2007

Suppliers with verified business licenses

Rating: 5.0/5

Basic Info.

Model NO.
S11-MS-6300/10
Usage
Power Transformer
Frequency Characteristics
High Frequency
Shape of Core
Ring
Brand
Ville
Voltage
6kv, 10kv
Voltage Regulation
off Circuit Tap Regulation
Transport Package
Wooden Case or as Per Requirement
Specification
IEC CE, ISO
Trademark
VILLE INDUSTRY
Origin
Ningbo China
HS Code
8504231200
Production Capacity
1000 Sets/Year

Product Description

Technical Specification:
Voltage: 6kV, 10kV class;
Voltage regulation: off circuit tap regulation;
Tapping range: ±5%, ±2X2.5%;
Capacity range: 30-2500kVA;
Frequency: 50Hz, 60Hz;
Phase: single phase and 3-phase;
Vector group: Yyn0 or Dyn11
Impedance voltage: in line with national standard or according to customer's requirements;
Operation environment: max.temperature for outdoor operation environment ≤ 40°C (or according to customer
requirements);
Cooling method: oil immersed ONAN;

35KV Oil-Immersed Distribution 
20kV(11KV) SZ11 Series three phases low lose oil-immersed on-load regulation distribution transformer(copper
winding)
Introduction
1.3Ph,HV:(6,6.3,10.5,11,15KV )  LV:(0.415,0.4,0.69 KV)
2,Rated Capacity:10kVA~20MVA
 
Transformer Standard

GB 1094.3-2003( IEC 60076-3-2000) 
 
Service Condition
1) Altitude: ≤1, 000m
2) Max. ambient temperature: +40.C
3) Max. daily average temperature: +30.C
4) Max. annual average temperature: +20.C
5) Minimal ambient temperature: -25.C
6) Indoor or outdoor 
  
Tech data of 10kV SZ11 series on-load regulation distribution transformer
Rated capacity
(KVA)
Voltage group
(kV)
Vector group Impedance voltage
(%)
Loss(kW) No-load current 
(%)
Weight(kg) Outline dimension (mm) Gauge vertical/
Horizontal
No-loss Load Body Oil Total
200 (HV)   6-15kV (LV) 0.415-6kV Yyno Dyn11 4 0.34 3.06 1.5 540 270 1110 1400*740*1190 550/550
250 0.4 3.6 1.4 640 290 1270 1420*790*1210 660/660
315 0.48 4.32 1.4 730 320 1500 1540*850*1240 660/660
400 0.57 5.22 1.3 940 370 1780 1590*940*1250 660/660
500 0.68 6.21 1.3 1040 370 1920 1650*1000*1350 660/660
630 4.5 0.81 7.65 1.1 1220 460 2280 1810*1140*1350 820/820
800 0.96 9.36 1 1500 500 2740 1890*1200*1310 820/820
1000 1.15 10.98 1 1610 520 3060 1910*1260*1570 820/820
1250 1.36 13.05 0.9 1880 700 3710 1960*1280*1740 820/820
1600 1.64 15.57 0.8 2290 780 4350 2330*1800*1910 820/820
2000 1.96 21.26 0.8 2560 900 4950 2580*1900*1950 820/820
2500 2.31 24.69 0.7 3170 1010 6020 2580*1940*2250 1070/1070
Note:it can supply voltage regulating range of ±4*2.5%for HV on load regulation transformers


6300kVA 10kv Three Phase Petrochemical Transformer Power Transformers for Refining and Petrochemicals

Workshop

6300kVA 10kv Three Phase Petrochemical Transformer Power Transformers for Refining and Petrochemicals
Our Best Service For You
1. Pre sale service
a. make technical solution
b. send quotation, technical data sheet and drawing
c. prepare power transmission plan, testing plan and shipment plan
2. In sale service
a. supervise the manufacturing schedule totally in accordance with the plan
b. send photos to customer during every manufacturing process(hold point)
c. inform the customer one week before testing.
3. After sale service
a. installation and commissioning, training the workers
b. quick response within 12 hours any time
c. provide 12 months guarantee period normally.



Order Instructions
When you choose our company product, please offer following data:
Transformer model:                     
Rated capacity:                     kVA
Phase       :    Three-phase
  • Single-phase
Frequency   :     50HZ
  •  60HZ
Rated voltage ( H.V. / L.V. ):                
Tapping range: ±       ×       %
Insulation level: LI       AC       / LI       AC        kv
Veotor group:  Dyn11
             Yyno
             Other
Short-circuit Impedance:        %
Cooling method:  ONAN
                ONAF
Tapping method:  OLTC
                OCTC
                Other
Other requirement:                                            

Notes:
  1. We also can design special products according to customer's particular requirements.
  2. The final dimension is subject to outline drawing.

Thanks for choosing VILLE as your reliable partner and
please trust both of us will create a brilliant future!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2007

Suppliers with verified business licenses

Rating: 5.0/5
Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, IATF16949, ISO 14064, QC 080000, ANSI/ESD, ISO 29001, ISO 50001
Import & Export Mode
Have Own Export License
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram