• Ring Main Unit Metal-Clad Switchgear
  • Ring Main Unit Metal-Clad Switchgear
  • Ring Main Unit Metal-Clad Switchgear
  • Ring Main Unit Metal-Clad Switchgear
  • Ring Main Unit Metal-Clad Switchgear
  • Ring Main Unit Metal-Clad Switchgear

Ring Main Unit Metal-Clad Switchgear

Task: Adjust
Structure: Open-Loop
Mathematical Model: Linear
Signal: Continuous
Function: Automatic Control
Certification: ISO: 9001
Customization:
Gold Member Since 2007

Suppliers with verified business licenses

Rating: 5.0/5

Basic Info.

Model NO.
12kv 24kv 35kv
Condition
New
Customized
Customized
Material
Stainless Steel
Endurance of Equipment
30years
Test
Type Test Report
Transport Package
Wooden Cases
Specification
IEC Standard
Trademark
VILLE
Origin
Ningbo China.
HS Code
8543709990
Production Capacity
1/Month

Product Description

Introduction:
HXGN26-12(F) Combined Metal-clad AC Ring Main Unit Switchgear ( hereafter referred to as Ring Main Unit )
are designed and manufactured by ourselves by importing foreign advanced technology and accord with the
requirement of power supply in our country.

Product Feature:
A. Main switch is FN26-12 SF6 load;
B. Three phases are end to end arrangement;
C. Two mechanisms: Manualmanual and motor drive;
D. Enclosure: Complete aluminum zinc coated steel plate;
E. Reliable 5 protection interlock system;
F. Easy control circuit connection between cabinets.

Technical parameters:
Rated voltageKV35
Max system voltageKV38, 5
Power frequency withstand voltage
Phase - earth and phase - phase--KV75
Opened contactKV85
Lightning impulse withstand voltage
Phase - earth and phase - phase--KV180
Opened contactKV195
Short circuit withstand current (1s)KA20
Short-circuit current indicators (manual setting) for cable in and out
Capacitor voltage indicator
Conformity for remote contron in futureComply

Min. Thickness of metall shell of SF6 camera SF6 Mm
T-Plug for cables in and out
Elbow for cable to transformer
The annual relative leakage of gas-filled compartment
%/year£ 0, 1
Name Unit Data
Rated voltage kV 12
Rated frequency Hz 50
Rated current of main busbar A 630
Rated short-time withstand current of main circuit and earthing circuit. kA/s 25/2
Rated peak withstand current of main circuit and earthing circuit. kA 63
Rated short-circuit making current of main circuit and earthing circuit. kA 63
Load switch full capacity breaking  times times 100
Fuse breaking current kA 31.5 40
Mechanical endurance times 10000
1min power frequency withstand voltage(r. m. s) phase to phase, phase to earth/isolating distance kA 42/48
Lightning impulse withstand voltage (peak)phase to phase, phase to earth/ isolating distance kV 75/85
Secondary circuit 1min power frequency withstand voltage kV 2

Ring Main Unit Metal-Clad Switchgear
Our advantages:
Quality Assurance
--From the very beginning, VILLE ensures quality in every step to achieve the best quality.
 Experience Sharing
--With more than 30 years' experience in power industry, VILLE brings you an optimized solution.
 Global Service
--Wherever you are, VILLE global network will support and provide you with value.
 Quick Response
--In response to your needs without delay, VILLE  knows the value of your time.

Thanks for choosing VILLE as your reliable partner and
please trust both of us will create a brilliant future!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2007

Suppliers with verified business licenses

Rating: 5.0/5
Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, IATF16949, ISO 14064, QC 080000, ANSI/ESD, ISO 29001, ISO 50001
Import & Export Mode
Have Own Export License
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram