General:
XGN56-12 (XGT3-12) Cubicle Fixed AC Metal-clad Switchgear (following abbreviation switchgear) is a lastest
version of high voltage electrical complete set of equipment which designed and developed by self, it fits
national standard GB3906 " 3-35kV's AC metal switchgear" and power ministry requirement of DL 404 "indoor
AC HV switchgear's technology requirement of order", and also satisfied requirement of international standard
IEC 298 " AC metal sealed switchgear and control equipment which rated voltage is 1kV to 52kV", and
possesses the ability of " five guards against" required by two ministries.
This product has absorbed the advanced technology of abroad, and design and develop by self according to
the question of higher accident rate in running and large volume at present the same's switchgear of our
country occurs, and it posses the merits of small volume, only 50% with ordinary switchgear volume, high
reliability, good capability, "five guards against" interlocking mechanism is reliable and simple etc.
Application:
The switchgear is suitable in indoor complete set of device which 3.6~12kV three-phase AC 50Hz single-
bus burst, it used as electric energy accepting and distributing and possess the merit of control and protects
and monitoring to the circuit etc. It can be used in all kinds of power plant and power station industrial and
mining enterprises, high-rise building, etc. And can also be used in open and close place with RMU.
Technical Data:
Rated Voltage (kV) |
12 |
Rated Insulation Level |
Rated 1min power frequency
withstand voltage |
42 |
Lighting impulse withstand
voltage |
75 |
Rated Frequency |
50 |
Main Busbar Rated Current |
630 |
1250 |
2000 2500 3150 |
Branch Busbar Rated Current |
630 |
1000 1250 |
2000 2500 3150 |
4s Rated short-time withstand current (r.m.s.) (kA/s) |
20 |
31.5 |
40 |
Rated Peak Withstand Current |
50 |
80 |
100 |
Degree of protection |
IP3X |
Dimensions (Width×Depth×Height) mm |
900×1050×2300 |
1050×1050×2300 |
Ordering Notice:
Please provide the followings
A. Main wiring scheme code, single line system diagram, pareto diagram and layout plan.
B. Secondary principle diagram, terminal pareto diagram. If without it, conform with the manufacturer's terminal
pareto diagram.
C. The type, specification and quantity of the electrical components of switchgear.
D. Summary table of electrical equipment.
E. Please provide span and height dimensions if busbar bridge(between two ranks of switchgear or between
switchgear and wall) is needed.
F. Please indicate if switchgear shall be on the special condition.
G. Please indicate type and quantity of other accessories, if necessary.
Our advantages:
Quality Assurance
--From the very beginning, VILLE ensures quality in every step to achieve the best quality.
Experience Sharing
--With more than 30 years' experience in power industry, VILLE brings you an optimized solution.
Global Service
--Wherever you are, VILLE global network will support and provide you with value.
Quick Response
--In response to your needs without delay, VILLE knows the value of your time.
Thanks for choosing VILLE as your reliable partner and
please trust both of us will create a brilliant future!