Product Description
Features
FM160 intelligent resistor monitoring device during normal system operation can be monitored when the neutral unbalance current, resistor temperature (the highest temperature up to 1000 ºC); single-phase ground fault,can record instant resistance,grounding time,sheet resistance temperature changes and ground operation frequency and RS485 communication interface, MODBUS protocol to be seized. Measured, recorded information is transmitted to the control room or computer unit, remote control. Intelligent control section in strict accordance with the implementation of the relevant national standards for manufacturing.
Neutral grounding resistors are made of special stainless steel electric-heat metal imported from US.They are with outstanding characters such as high temperature-resistant capability,excellent anti-oxidation performance,strong tensile characteristics,high resistivety and stable resistance value,what's more,it can sustain elec-tric and thermodynamic performance even under 1000°C,which enables safe and reliable operation.
According to different connection mode or various customer requests,we can provide epoxy resin to cast dry type transformers,zero sequence current transformers,single-phase discon-necting switches,heater and thermo/humidity controllers etc.
Voluntary Standards
DL/T780-2001 Neutral grounding resistors in electric power distribution system
GB6450 Dry type Electric transformer
DL/T620-1997 Over-voltage protection and insulation coordination for AC equipment
GB/T16927-1997 High-voltage testing technology
GB1208-1997 Current transformer
GB4208-1993 Protection level of enclosure(IP Code)
IEE32-1972 Technology,terms and test of neutral grounding resistors
GB311.1-1997 Insulation coordination of high-voltage transmitting and distribution equipment
DL/T593-1996 Common order technical requirements of high- voltage switch equipment
GB/T11022-1999 Electric equipment delivery testing criterion of electric device installation Other national criterion and electric power industry standards.
Product Parameters
Operation Environment
Air Temperature:≥-35°C,≤+50°C
Altitude:≤1000m(general)
Wind pressure: ≤700 Mpa(equal to wind speed at 34 m/s)
Earthquake intensity: ≤magnitude 8
lce cover: ≤15mm
Air contamination level:≤IV
Product Categories
The low resistance grounding resistor for electric power distribution networks
The moderate resistance grounding resistor for electric power distribution networks
The high resistance grounding resistor for electric power distribution networks
The high resistance grounding resistor for generators
Parameters of products
Voltage:0.4kV~110kV;
Rated current:optional;
Nominal resistance:optional;
Current duration:10s,30s,60s,10min,continuous;
Incoming and outing line:top in bottom out,bottom in bottom out,side in side out,side in bottom out,etc;
Installation site:indoor/outdoor;
Allowable temperature rise:760°C for 10s,30s,60s and 610°Cfor 10min and 385°C for continuous
Zero sequence current transformer:optional
| Type |
Rated Voltage
of system |
Rated Voltage
of resistor |
Rated current |
Current
duration |
(Ω) ±10% Nominal resistance value |
W×D×H (mm) Dimension |
(kg) Weight |
| NGR-6.3/100-10 |
6.3 |
3.64 |
100 |
10 |
36.4 |
1300 ×1300 ×1900 |
450 |
| NGR-6.3/200-10 |
6.3 |
3.64 |
200 |
10 |
18.2 |
500 |
| NGR-6.3/400-10 |
6.3 |
3.64 |
400 |
10 |
9.09 |
500 |
| NGR-6.3/600-10 |
6.3 |
3.64 |
600 |
10 |
6.06 |
500 |
| NGR-6.3/1000-10 |
6.3 |
3.64 |
1000 |
10 |
3.64 |
500 |
| NGR-10/100-10 |
10 |
5.77 |
100 |
10 |
57.7 |
500 |
| NGR-10/200-10 |
10 |
5.77 |
200 |
10 |
28.9 |
550 |
| NGR-10/400-10 |
10 |
5.77 |
400 |
10 |
14.4 |
550 |
| NGR-10/600-10 |
10 |
5.77 |
600 |
10 |
9.62 |
550 |
| NGR-10/1000-10 |
10 |
5.77 |
1000 |
10 |
5.77 |
550 |
| NGR-20/600-10 |
20 |
11.5 |
400 |
10 |
28.9 |
1700 ×1700 ×2600 |
1250 |
| NGR-20/600-10 |
20 |
11.5 |
600 |
10 |
19.2 |
1250 |
| NGR-35/200-10 |
35 |
20.2 |
200 |
10 |
101 |
3000 ×1700 ×2600 |
2000 |
| NGR-35/400-10 |
35 |
20.2 |
400 |
10 |
50.5 |
2000 |
| NGR-35/600-10 |
35 |
20.2 |
600 |
10 |
33.7 |
2000 |
| NGR-35/1000-10 |
35 |
20.2 |
1000 |
10 |
20.2 |
2000 |
| NGR-35/1300-10 |
35 |
20.2 |
1300 |
10 |
15.5 |
3000 ×1700 ×3100 |
2500 |
| NGR-35/2000-10 |
35 |
20.2 |
2000 |
10 |
10.1 |
250 |
Packaging & Shipping
Packing, Transportation, Storage
The package should be placed on sleeper by normal position and fastened by bolt;
The cabinet should be covered with foam to be protected against dust and vapor during the transportation;
Keep the equipment in its original package when deliver to installation field, so as to prevent it from possible damage during the transportation;
Fix it with fastener to prevent it from resistor looseness during the transportation;
Seal the box with lath;
Indicate delivery place, equipment name, weight etc on the packing box clearly;
All the boxes can be lifted to the common container by forklift;
Unload the goods with forklift or crane after its arrival;
Inspect the goods after unloading to make sure that the goods is in good condition.
Packaging Details:each in foam box or Packaging Details:wooden pakage
Company Profile

Our Performance:
| 1. |
Pre sale service |
| a. |
make technical solution |
| b. |
send quotation, technical data sheet and drawing |
| c. |
prepare power transmission plan, testing plan,and shipment plan |
| 2. |
In sale service |
| a. |
supervise the manufacturing schedule totally in accordance with the plan |
| b. |
send photos to customer during every manufacturing process(hold point) |
| c. |
inform the customer one week before testinng. |
| 3. |
After sale service |
| a. |
installation and commissioning, training the workers |
| b. |
quick response within 12 hours any time |
| c. |
provide 12 months gurantee period normally. |
FAQ For You
| 1. Q: |
What is your delivery time ? |
| A: |
Depend on the type of transformer. |
| 2. Q: |
What is your payment term? |
| A: |
30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it. |
| 3. Q: |
What kind of starndard you follow? |
| A: |
IEC, ANSI, CSA, GB, etc |
| 4. Q: |
What kind of supporting documentation you can provide normally |
| A: |
Quotation,outline drawing,manufacturing plan, quality control plan,testing plan, financial report, type test report(KEMA, CESI),reference list,etc |
| 5. Q: |
What is your normal wanrranty period? |
| A: |
12 months after transformer operation. |
| 6. Q: |
Can u do installation and commissioningin user's site? |
| A: |
Yes, we can send our installation team to user's country for service. |
| 7. Q: |
Do you have any experience in this kind of transformer? |
| A: |
Yes, we can provide reference list for check. |
| 8. Q: |
Are you manufacturer or trading company? |
| A: |
Manufacturer and Trading company. |
Our advantages:
Quality Assurance
--From the very beginning, VILLE ensures quality in every step to achieve the best quality.
Experience Sharing
--With more than 30 years' experience in power industry, VILLE brings you an optimized solution.
Global Service
--Wherever you are, VILLE global network will support and provide you with value.
Quick Response
--In response to your needs without delay, VILLE knows the value of your time.
Thanks for choosing VILLE as your reliable partner and please trust both of us will create a brilliant future!