Zhejiang, China
Management System Certification:
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, ISO/TS 16949, ISO 14064, QC 080000, ...
Import & Export Mode:
Have Own Export License
Terms of Payment:
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms):
FOB, CFR, CIF, FCA, EXW
OEM/ODM Availability:
Yes
OEM/ODM Service
Sample Available
MEI Awards

Indoor Ac Hv Load Switch, Load Switch, Vacuum Load Switch manufacturer / supplier in China, offering Indoor AC Hv Load Switch, Three Phase Filter Reactor, Harmonic Filter Reactor and so on.

Gold Member Since 2007
Audited Supplier

Indoor AC Hv Load Switch

Get Latest Price
Min. Order: 1 Piece
Production Capacity: 50000 Sets/Year
Transport Package: Wooden Cases
Payment Terms: L/C, T/T, D/P
Breaking Capacity: High Voltage Circuit Breakers
Type: load switch
Operation: Electric Type
Installation: Fixed
Speed: Normal Type Circuit Breaker
Structure: Moulded Case Circuit Breaker

You Might Also Like

Loading...

Basic Info

Model NO.: Fn3-12 Series
Arc-extinguishing Medium: Air
Function: Overcurrent Protection, Circuit-Breaker Failure P
Certification: CE, ISO9001-2000, CCC, VDE, UL, CB
Trademark: VILLE
Specification: IEC standard
Origin: Ningbo China

Product Description

General:
FN3-12 series indoor AC HV load switch is suitable for AC 50Hz, 10kV three-phase power system for breaking and closing load current, also for breaking and closing long no-load line and capacitor bank capacitance current. Load switch with fuse(FN3-12R\FN3-12R/S)can break short-circuit current and protect switches.
The load switch can be fitted with CS3 and CS2 type manual operating mechanisms.

Characteristics:

FN3-12 series indoor AC HV load switch has a similar appearance as common indoor AC HV load switches with frame containing drive mechanism under the switch. There are six insulators on top of the frame, the upper three of them work as support and cylinder. The piston is installed inside the cylinder and driven by main shaft. The lower three of them work as support. Both the upper and lower insulators have contact holder that is the three-phase circuit input and output terminal. Conducting parts are made up of switch blade and contact holder. The switch blade and lower contact holder are fixed by six butterfly springs. At the end of switch blade there is arc contact. The upper contact holder is main static contact.
 
Type
Rated voltage
kV
Rated current
A
Thermal stable current
kA/s
Dynamic stable current
kA
FN3-12 12 400 12.5/2 31.5
Technical parameter of load switch fitted fuse:

Type Rated voltage
kV
Fuse rated current
A
Rated breaking current
kA
Fuse link rated current
RN3 12 50 12.5 2, 3, 5, 7.5, 15, 20, 30, 40, 50
75 75
100 100
200 150 200
SDL*J 12 40 50 6.3, 10, 16, 20, 31.5, 40
SFL*J 12 100 50, 63, 71, 80, 100
SKL*J 12 125 125