Technical paramters:
Rated Capacity(MVA): |
50 |
Voltage ratio HV(KV): |
69 |
Voltage ratio LV(KV): |
6.3 |
Voltage ratio HV Tapping Range(kv): |
± 8 x 1.25% |
Connection symbol: |
YND11 |
No-load Loss(KW): |
47.6 |
No-load Current(%): |
0.4 |
Full-load Loss(KW): |
184.5 |
Impedance(%): |
9 |
Reference Temperature |
° C |
75 |
No-Load Losses at Principal Tapping: |
W |
9.0 kW |
Looses of Cooling Fan System |
W |
/ |
Insulation Levels (LI/AC): |
|
LI325AC140/LI125AC55 |
No Load Current: |
@ Un |
% In |
0.56 |
@ 1.05 Un |
% In |
0.68 |
Sound Level: |
dB |
< 67 |
Short Circuit Impedance at Principal Tapping: |
P/S |
% Un |
8~10% |
P/T |
% Un |
|
S/T |
% Un |
|
Reference Temperature |
° C |
75 |
Top Oil Temperature Rise: |
°C |
51K |
Average Winding Temperature Rise: |
°C |
64K |
Insulation Resistance (Reference Temperature = 20°C): |
|
|
HV/LV / |
Mohms |
≥1000 |
HV/GR - LV/GR - |
Mohms |
≥1000 |
Order Instructions
When you choose our company product, please offer following data:
Transformer model:
Rated capacity: kVA
Phase:Three-phase
Single-phase
Frequency:50HZ
60HZ
Rated voltage ( H.V. / L.V. ):
Tapping range: ± × %
Insulation level: LI AC / LI AC kv
Veotor group: Dyn11
Yyno
Other
Short-circuit Impedance: %
Cooling method:ONAN
ONAF
Tapping method:OLTC
OCTC
Other
Other requirement:
Notes:
We also can design special products according to customer's particular requirements.
The final dimension is subject to outline drawing.
Our Performance:
1. |
Pre sale service |
a. |
make technical solution |
b. |
send quotation, technical data sheet and drawing |
c. |
prepare power transmission plan, testing plan,and shipment plan |
2. |
In sale service |
a. |
supervise the manufacturing schedule totally in accordance with the plan |
b. |
send photos to customer during every manufacturing process(hold point) |
c. |
inform the customer one week before testinng. |
3. |
After sale service |
a. |
installation and commissioning, training the workers |
b. |
quick response within 12 hours any time |
c. |
provide 12 months gurantee period normally. |
FAQ For You
1. Q: |
What is your delivery time ? |
A: |
Depend on the type of transformer. |
2. Q: |
What is your payment term? |
A: |
30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it. |
3. Q: |
What kind of starndard you follow? |
A: |
IEC, ANSI, CSA, GB, etc |
4. Q: |
What kind of supporting documentation you can provide normally |
A: |
Quotation,outline drawing,manufacturing plan, quality control plan testing plan, financial report, type test report(KEMA, CESI),reference list,etc |
5. Q: |
What is your normal wanrranty period? |
A: |
12 months after transformer operation. |
6. Q: |
Can u do installation and commissioningin user's site? |
A: |
Yes, we can send our installation team to user's country for service. |
7. Q: |
Do you have any experience in this kind of transformer? |
A: |
Yes, we can provide reference list for check. |
8. Q: |
Are you manufacturer or trading company? |
A: |
Manufacturer and Trading company. |
Ville Electric Company will keep up with the century, the epoch,
Sincerely look forward to your cooperation and win-win!
Create brilliant!