Oil-Immersed Type Load Break Switch for Oil-Immersed Transformer

Product Details
Customization: Available
Application: Power
Phase: Three
Gold Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, IATF16949, ISO 14064, QC 080000, ANSI/ESD, ISO 29001, ISO 50001
Import & Export Mode
Have Own Export License
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
  • Oil-Immersed Type Load Break Switch for Oil-Immersed Transformer
  • Oil-Immersed Type Load Break Switch for Oil-Immersed Transformer
  • Oil-Immersed Type Load Break Switch for Oil-Immersed Transformer
  • Oil-Immersed Type Load Break Switch for Oil-Immersed Transformer
Find Similar Products

Basic Info.

Model NO.
"T" Type "V" Type "I" Type bfy
Core
Core-type Transformer
Cooling Method
Oil-immersed Type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001
Usage
Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Frequency Characteristics
Power Frequency
Brand
Ville
Structure
Double-Column Disconnector
Grounding Mode
Not Grounding
Movement Mode
Vertical Rotary Type
Number of Poles
Three Pole
Grounding
Un Grounded
Series
Three
Run
Vertical Rotation
Switching Mode
Double-Throw Type
Common Model
Vr
Use for
Compounded Type Transformer
Classification
Four-Position and Two-Position Products
Installation Position
Tank Well of Compounded Transformer
Rated Frequency
50Hz
Rated Voltage
10kv and 35kv
Rated Current
315 a and 630A.
Transport Package
Wooden Case
Specification
IEC CE, ISO
Trademark
VILLE
Origin
Ningbo
HS Code
8504231100
Production Capacity
50000 Sets

Product Description

Application:
This switch is used for compounded type transformer. It is classified into four-position and two-position
products. The four-position switch is divided into "T" type, "V" type and "I". The switch is installed on the tank
well of compounded transformer, the transformer oil is used for its insulating and are eliminated material. It is
suitable for three phase power supply circuit with rated trequency 50Hz, rated voltage 10kV, 35kV, rated current
315 A and 630A. In the radial feed or loop feed supply system, it is used as controlling and protective device in
the industry civil used electric energy. When functioned by operating pole, the switch can drive three phase
linkage cut and close power resource or transfer supply method.

The on-load switch our company manufactures has innovative structure, excellent performance and high
reliability. It is tested qualified in every technical index b the National Transformer Quality Supervision and
Inspection Center. Its main features are as follow:

Feature:
1.The fixed contact of the same kind product is crab-claw form. With the increasing rotation of the switch, the
movable contact wears out more heavily, the pressure fixed contact put onto the movable contact declines, and
the contact resistance increases.
We change the fixed contact into clip-chip, and connect it with soft-connecting films, ensuring the contact
pressure with cylindrical spring to maintain a high contact pressure after 2000 times shifting and enable a
minimum contact resistance of fixed and movable contact. We also use high-quality copper alloy as the contact
material to make a lightest damage the arc will do to the contact when the contact shifts on-load, and enlarge
the contacting area to improve the current-passing capability.
2. Key components of our switch apply the overall steel casting technology, so the products are with high
mechanical strength.
3. Each plate-form spring has a deformation test before assembly to ensure the quality of the spring.
4. We use the latest type of insulation materials to ensure the switch a higher capability of withstand voltage
and withstand voltage.

Technical parameters:
Rated voltage (kV) Power frequency withstand voltage (1min) (kV) Lighting withstand voltage (kV)
To ground or inter phase Insolating insulation between gaps To ground or inter phase Insolating insulation between gaps
10 42 48 75 85
20 55 60 125 145
35 95 110 200 215
 
Type of tap changer Rated current (A) Rated Voltage
(kV)
Install Dimension (mm)
H H1 H2 H3 L L1
BFY312-10/315-12.5-II 315 10 465 37 86 172 187 102
BFY312-10/630-16-II 630
BFY312-20/315-16-II 315 20 500 43 97 180 222 120
BFY312-20/630-20-II 630
BFY312-35/315-16-II 315 35 540 43 110 195 222 120
BFY312-35/630-20-II 630
BFY311-10/315-16-IV 315 10 525 30 105 195 280 225
BFY311-10/630-20-IV 630
BFY3V1-10/315-16-IV 315
BFY3V1-10/630-20-IV 630
BFY3T2-10/315-16-IV 315 485 30 86 189 206 136
BFY3T2-10/630-20-IV 630
BFY3T1-20/315-16-IV 315 20 540 30 105 210 280 225
BFY3T1-20/630-20-IV 630
BFY3T1-35/315-16-IV 315 35 590 36 114 238 272 176
BFY3T1-35/630-20-IV 630
Oil-Immersed Type Load Break Switch for Oil-Immersed Transformer
Company profile:
Main product line: Tap changer and HV switchgear
Tap changer manufacturing with fullest vertical integration
Tap Changer Products Range On-Load Tap Changer:
* Conventional OLTC for transformer with voltage up to 765kV
*Vacuum OLTC for oil transformer with voltage up to 765kV
*Vacuum OLTC for dry transformer with voltage of 72.5kV
Off-Circuit Tap Changer
* Application for the transformer with voltage up to 765kV
Oil-Immersed Type Load Break Switch for Oil-Immersed Transformer
Our Services
1. Pre sale service
a. make technical solution
b. send quotation, technical data sheet and drawing
c. prepare power transmission plan, testing plan and shipment plan
2. In sale service
a. supervise the manufacturing schedule totally in accordance with the plan
b. send photos to customer during every manufacturing process(hold point)
c. inform the customer one week before testing.
3. After sale service
a. installation and commissioning, training the workers
b. quick response within 12 hours any time
c. provide 12 months guarantee period normally.

FAQ
1. Q: What is your delivery time ?
A:  Depend on the type of transformer.
2. Q: What is your payment term?
A:  30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it.
3. Q: What kind of standard you follow?
A:  IEC, ANSI, CSA, GB, etc
4. Q: What kind of supporting documentation you can provide normally
A:  Quotation, outline drawing, manufacturing plan, quality control plan
testing plan, financial report, type test report(KEMA, CESI),reference list, etc
5. Q: What is your normal warranty period?
A:  12 months after transformer operation.
6. Q: Can u do installation and commission in user's site?
A:  Yes, we can send our installation team to user's country for service.
7. Q: Do you have any experience in this kind of transformer?
A:  Yes, we can provide reference list for check.
 
Our advantages:
Quality Assurance
--From the very beginning, VILLE ensures quality in every step to achieve the best quality.
 Experience Sharing
--With more than 30 years' experience in power industry, VILLE brings you an optimized solution.
 Global Service
--Wherever you are, VILLE global network will support and provide you with value.
 Quick Response
--In response to your needs without delay, VILLE  knows the value of your time.
 
Thanks for choosing VILLE as your reliable partner and
please trust both of us will create a brilliant future!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier