Outdoor Switchgear with Vacuum Circuit Breaker 33kv with Protection Relay with Current Transformer and Voltage Transformer

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Gold Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, IATF16949, ISO 14064, QC 080000, ANSI/ESD, ISO 29001, ISO 50001
Import & Export Mode
Have Own Export License
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
  • Outdoor Switchgear with Vacuum Circuit Breaker 33kv with Protection Relay with Current Transformer and Voltage Transformer
  • Outdoor Switchgear with Vacuum Circuit Breaker 33kv with Protection Relay with Current Transformer and Voltage Transformer
  • Outdoor Switchgear with Vacuum Circuit Breaker 33kv with Protection Relay with Current Transformer and Voltage Transformer
  • Outdoor Switchgear with Vacuum Circuit Breaker 33kv with Protection Relay with Current Transformer and Voltage Transformer
  • Outdoor Switchgear with Vacuum Circuit Breaker 33kv with Protection Relay with Current Transformer and Voltage Transformer
  • Outdoor Switchgear with Vacuum Circuit Breaker 33kv with Protection Relay with Current Transformer and Voltage Transformer
Find Similar Products

Basic Info.

Model NO.
33KV Vacuum Circuit Breaker
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Vacuum
Installation
Open Frame
Structure
Moulded Case Circuit Breaker
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker
Certification
VDE, ISO9001-2000, CE, CB, CCC
Installation Site
Outdoor
Voltage
40.5kv
Current
2000A
Phase
3
Transport Package
Wooden Cases
Specification
IEC standard
Trademark
VILLE
Origin
Ningbo China
HS Code
85
Production Capacity
50000 Sets/Year

Product Description

General:
ZW30-40.5/2000-31.5 outdoor HV vacuum circuit breaker (hereinafter referred to as ZW30-40.5) can be used
in the power system with rated voltage 40.5KV, rated current 2000A and three - phase AC 50HZ to protect the
equipment in the industrial and mineral enterprises, power plants and substations, which can be used as a
connecting circuit breaker in the workplaces of frequent operation.
This product complies with the standards of the GB1984-89 AC HV Circuit Breaker, IEC56 HV AC Circuit
Breaker and JB3385-1996 3.6-40.5KV Indoor AC HV Vacuum Circuit Breakers.

Features:
A, This product is for outdoor high voltage vacuum circuit breaker, the overall structure of the ceramic column,
a vacuum interrupter in the porcelain, the circuit breaker under the outlet end of the use of the slider-type
contact, the product has a smaller loop resistance and good oriented, the next set of ceramic pillar, to ensure
live parts of the insulation, ceramic kit has absolutely bar, mounted on a common three-phase bottom box on
the upper and lower porcelain comprising a charge 0.02Mpa (20 c) the provisions of gas.
B, the product with 1 to 6 can be independent of the current transformers, transformers can be installed into the
circuit breaker or the outlet end of the line side, or both ends installed. Independent of the current transformer
under its accuracy at any level can meet user requirements, and can be done once or twice without disturbing
each other.
C, with a special trip the circuit breaker signs device that can be read at any time convenient to the vacuum
interrupter trip and overtravel.
D, the circuit breaker oil with excellent cushioning buffer and sub-gate stopper.
E, the circuit breaker is equipped with CT17-IVB-type spring operating mechanism.
 
NO Name Unit Data
1 Rated voltage KV 40.5
2 Rated insulating level Rated 1min power frequency withstand voltage Dry test (fracture,phase-to-phase,phase-to-earth) 95*
Wet test (to earth, external insulation) 80*
Lightning impulse withstand voltage (crest) 185*
3 Rated current A 2000
4 Rated short-circuit breaking current KA 31.5
5 Rated short-circuit making current( crest) 80
6 Rated operative sequence 0-0.3sCO**-180s-CO**
7 Rated out-of-phase breaking current KA 8
8 The rated single condenser group breaking current A 630
9 Rated short-circuit lasting time S 4
10 Rated short-circuit breaking times Times 20
11 Arcing time Ms <20
12 Fully breaking time Ms <=85
13 Mechanical endurance( CO) Times 10000
14 Rated charge pressure Apply TD-40.5W/2000-31.5( K) Vacuum arc-chute filled with SF6 Mpa 0.02( 20ºC)
Apply TD-40.5W/2000-31.5( K) Vacuum arc-chute filled with dry air and pure nitrogen
15 Annual leakage rate % <=1
16 The degree of vacuum 
arc-chute
Arc-chute newly produced Pa <=1.33X10 -3
Storage period for 20 years < 6.6X10 -2
Outdoor Switchgear with Vacuum Circuit Breaker 33kv with Protection Relay with Current Transformer and Voltage Transformer
Outdoor Switchgear with Vacuum Circuit Breaker 33kv with Protection Relay with Current Transformer and Voltage TransformerOutdoor Switchgear with Vacuum Circuit Breaker 33kv with Protection Relay with Current Transformer and Voltage Transformer
Our Services
1. Pre sale service
a. make technical solution
b. send quotation, technical data sheet and drawing
c. prepare power transmission plan, testing plan,and shipment plan
2. In sale service
a. supervise the manufacturing schedule totally in accordance with the plan
b. send photos to customer during every manufacturing process(hold point)
c. inform the customer one week before testinng.
3. After sale service
a. installation and commissioning, training the workers
b. quick response within 12 hours any time
c. provide 12 months gurantee period normally.

FAQ
1. Q: What is your delivery time ?
A:  Depend on the type of transformer.
2. Q: What is your payment term?
A:  30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it.
3. Q: What kind of starndard you follow?
A:  IEC, ANSI, CSA, GB, etc
4. Q: What kind of supporting documentation you can provide normally
A:  Quotation,outline drawing,manufacturing plan, quality control plan
testing plan, financial report, type test report(KEMA, CESI),reference list,etc
5. Q: What is your normal wanrranty period?
A:  12 months after transformer operation.
6. Q: Can u do installation and commissioningin user's site?
A:  Yes, we can send our installation team to user's country for service.
7. Q: Do you have any experience in this kind of transformer?
A:  Yes, we can provide reference list for check.
   
   
 