Transformer on-Load Tap Changers with Multiple Coarse & Fine Regulation Transformer Switch

Product Details
Customization: Available
Type: High-Voltage
Structure: Single-Column Disconnector
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, IATF16949, ISO 14064, QC 080000, ANSI/ESD, ISO 29001, ISO 50001
Import & Export Mode
Have Own Export License
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
  • Transformer on-Load Tap Changers with Multiple Coarse & Fine Regulation Transformer Switch
  • Transformer on-Load Tap Changers with Multiple Coarse & Fine Regulation Transformer Switch
  • Transformer on-Load Tap Changers with Multiple Coarse & Fine Regulation Transformer Switch
  • Transformer on-Load Tap Changers with Multiple Coarse & Fine Regulation Transformer Switch
  • Transformer on-Load Tap Changers with Multiple Coarse & Fine Regulation Transformer Switch
  • Transformer on-Load Tap Changers with Multiple Coarse & Fine Regulation Transformer Switch
Find Similar Products

Basic Info.

Model NO.
CM
Installation
Indoor High-Voltage
Operation
Manual
Grounding Mode
Not Grounding
Movement Mode
Vertical Rotary Type
Number of Poles
Three Pole
Grounding
Un Grounded
Series
Three
Run
Turn The Horizontal
Switching Mode
Single Throw-in
Common Model
Cr
Structure of Operating
Electric
Certification
ISO, Is9001, ISO9001
Max Rated Current
600A 1500A
Connection Method
Y, D
Rated Voltage
3.3kv
Transport Package
Wooden Cases
Specification
IEC CE, ISO
Trademark
VILLE
Origin
Ningbo
HS Code
85
Production Capacity
50000 Sets

Product Description

CM On-Load Tap Changers with Multiple Coarse & Fine Regulation

General

CM on load tap changer (OLTC) applies to power and rectifier transformers with rated voltage 35kV, 63kV,
110kV,150kV and 220kV, maximum rated through current 600A for three poles and 1500A for single pole, to
change the taps under load for the purpose of voltage regulation. Three phase OLTCs are used at the
neutral point of the Y connection, the single phase OLTC may be used for any connections. CM OLTC is a
typical OLTC of combined structure, which consists of diverter switch and tap selector.
CM on load tap changer is to be fastened to the transformer tank cover by its tap changer head which serves
also for connecting to the motor driver CMA7 or SHM-III via the worm wheel reducer and bevel gear box for the
purpose of tap changing.
When CM OLTC is used without a change-over selector,the maximum operating positions available will be
18, and will be up to 35 when it is used with a change-over selector. (special design is exclusive).
This operating instruction includes all the necessary information for the installation and operation of CM OLTC.

Type designation
Transformer on-Load Tap Changers with Multiple Coarse & Fine Regulation Transformer Switch

Technical data of CM OLTC
Transformer on-Load Tap Changers with Multiple Coarse & Fine Regulation Transformer Switch

Transformer on-Load Tap Changers with Multiple Coarse & Fine Regulation Transformer Switch

Mechanical operation principle of the tap changer


The operation of tap change begins with the electric motor of the motor drive unit. The driving force is
transferred to the worm wheel reducer on the top cover of the tap change through driving shaft and belt
pulley box. After the reducer, it is actuated to the energy acumulation mechanism and the shaft which
passes through the diverter switch sown to the cylinder bottom.
There the cylinder bottom gear clutch is connected to the Geneva wheel mechanism of the tap selector.
The rotation of Geneva wheel makes the contacting bridge to rotate an angle corresponding to one step, thus
the connecting bridge will connected to the desired tap of the tap winding without load.

In the same time, the eccentric wheel of the energy accumulation mechanism makes the upper slide to
move along the guide rail. The spring between the upper and lower slide is compressed to store energy, the
cam wheel is locked by the clutch to hold the lower slide in its original position. When the upper slide moves to
the release position, the side wall of the upper slide makes the corresponding jaw to move away from the
locked cam wheel, thus releases the energy storage mechanism and operates the diverter switch. At this time,
the lower slide moves to the new position, the clutch jaw again engages with the cam wheel, the mechanism is
locked to prepare for the next tap change operation.
The motor drive mechanism automatically stops after performing one tap change.
Transformer on-Load Tap Changers with Multiple Coarse & Fine Regulation Transformer Switch
Company Profile:
Main product line: Tap changer and HV switchgear
Tap changer manufacturing with fullest vertical integration
Tap Changer Products Range On-Load Tap Changer:
* Conventional OLTC for transformer with voltage up to 765kV
*Vacuum OLTC for oil transformer with voltage up to 765kV
*Vacuum OLTC for dry transformer with voltage of 72.5kV
Off-Circuit Tap Changer
* Application for the transformer with voltage up to 765kV
Transformer on-Load Tap Changers with Multiple Coarse & Fine Regulation Transformer Switch

Transformer on-Load Tap Changers with Multiple Coarse & Fine Regulation Transformer Switch
Our Best Service For You
1. Pre sale service
a. make technical solution
b. send quotation, technical data sheet and drawing
c. prepare power transmission plan, testing plan and shipment plan
2. In sale service
a. supervise the manufacturing schedule totally in accordance with the plan
b. send photos to customer during every manufacturing process(hold point)
c. inform the customer one week before testing.
3. After sale service
a. installation and commissioning, training the workers
b. quick response within 12 hours any time
c. provide 12 months guarantee period normally.

FAQ For You
1. Q: What is your delivery time ?
A:  Depend on the type of transformer.
2. Q: What is your payment term?
A:  30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it.
3. Q: What kind of standard you follow?
A:  IEC, ANSI, CSA, GB, etc
4. Q: What kind of supporting documentation you can provide normally
A:  Quotation, outline drawing, manufacturing plan, quality control plan
testing plan, financial report, type test report(KEMA, CESI),reference list, etc
5. Q: What is your normal warranty period?
A:  12 months after transformer operation.
6. Q: Can u do installation and commission in user's site?
A:  Yes, we can send our installation team to user's country for service.
7. Q: Do you have any experience in this kind of transformer?
A:  Yes, we can provide reference list for check.

Our advantages:
Quality Assurance
--From the very beginning, VILLE ensures quality in every step to achieve the best quality.
 Experience Sharing
--With more than 30 years' experience in power industry, VILLE brings you an optimized solution.
 Global Service
--Wherever you are, VILLE global network will support and provide you with value.
 Quick Response
--In response to your needs without delay, VILLE  knows the value of your time.

Thanks for choosing VILLE as your reliable partner and
please trust both of us will create a brilliant future!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier