• 33kv 40000kVA Power Distribution Transformer
  • 33kv 40000kVA Power Distribution Transformer
  • 33kv 40000kVA Power Distribution Transformer
  • 33kv 40000kVA Power Distribution Transformer
  • 33kv 40000kVA Power Distribution Transformer

33kv 40000kVA Power Distribution Transformer

Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio, Power Plant, Power, Electronic, Instrument, Lighting, Rectifier, Audio, Power Plant
Phase: Three, Three
Core: Amorphous Alloy Transformer, Amorphous Alloy Transformer
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
33kv 40000kVA Power Distribution Transformer pictures & photos
33kv 40000kVA Power Distribution Transformer
US $80,000-800,000 / Set
Min. Order: 1 Set
Gold Member Since 2007

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5

Basic Info.

Model NO.
SFZ-40000/33
Cooling Method
Oil-immersed Type Transformer, Oil-Immersed Type Transformer
Winding Type
Customized, Customized
Certification
ISO9001-2000, ISO9001, ISO9001-2000, ISO9001, ISO9001-2000, ISO9001
Usage
Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer, Single-Phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer, Single-Phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Frequency Characteristics
50Hz 60Hz, 50Hz 60Hz
Shape of Core
Ring, Ring
Brand
Ville, Ville
Power
Transformer
Power Supply
Power Plant
Transport Package
Wooden Cases
Specification
IEC Standard
Trademark
VILLE
Origin
Made in China
HS Code
8504340000
Production Capacity
1set/6monthes

Product Description

Our factory can produce voltage with 500kV and below, capacity 1000MVA and below series oil immersed power transformers.
digesting the advanced technology at home and abroad, combined with the advanced technology at home and abroad and our company's experience in producing power transformers for many years, 
Through optimization and innovation, we have successfully produced a series of power transformers with low noise, low loss, low partial discharge and high short-circuit resistance,
Fully comply with and superior to national standards and International Electrotechnical Commission recommended standards.

Transformer Main functions and characters:

Bell type tank and the wave form shell.; Increase the strength of oil box, beautiful appearance;
Core is with D shape yoke, 45 angle seaming;
Core and oil box are well fixed and well protected on moving;
Reasonable wrapping method, in the interior and exterior structure of coil; Use support; Hard paper bucket
between coils increases the capacity of anti-shortcut;
Advanced assembling method such as cold pressing and welding technology, installing with sets of coil, paper
bucket production.

Technical parameters:
SFZ-40000/33 Power transformer
Name: Three-phase windings OLTC dual immersion air-cooled power transformers
Type: SFZ-40000/33
Rated voltage: 33/6.9kv
Rated power: 35000/40000kVA
Rated voltage ratio: 33± 3× 2.5%/6.9kV
Rated currency: 700/3347A
PHASE: THREE PHASE
Rated Frequency: 50Hz
Connection Symbol: Dyn11
Tap changer: On load tap changer
Impedance voltage%: 13+0.8%
Cooling way: ONAN/ONAF
Winding Insulation Level
Lightning impulse withstand voltage(Kv, peak value) 1 min Frequency Pressure(kv, virtual value)

Full-wave
Latest wave

HIGH voltage SIDE: 170 185 75
Low voltage side: 75 85 35
Low-voltage neutral point: 75 35

Insulation class Class A
Transformer windings of the Inter-field strength is not more than 2 Kv / mm
Transformer loss (below 75), the no-load current and efficiency
No-load loss: 21 kW
Load loss: 198 Kw
No-load current: 0.5%
Radio frequency interference and Corona
To the greatest work of the voltage, outdoor sunny evening out line without visible Corona, radio interference voltage is not more than 2500
UV.
 
Type Voltage compose and 
Tapping range (kV)
HV         LV             Connection
No-load 
Loss
(kW)
Load 
loss
(kW)
No-load 
current
(%)
Impedance 
voltage
(%)
Transport 
weight 
(t)
Gross 
weight 
(t)
Dimensions 
L×W×H (mm)
SZ9-2000/35 35
±3×2.5%
6.3
10.5




Yd11
2.88 18.7 1.00 6.5 4.93 5.97 3010×2070×2540
SZ9-2500/35 3.40 21.7 1.00 6.5 5.68 6.95 3040×2270×2610
SZ9-3150/35 4.04 26.0 0.90 7.0 6.08 7.90 3160×2300×2640
SZ9-4000/35 35
38.5
±3×2.5%
6.3
10.5
4.84 30.7 0.90 7.0 7.10 9.11 3300×2330×2890
SZ9-5000/35 5.80 36.0 0.85 7.0 8.47 10.86 3350×2520×3000
SZ9-6300/35 7.04 38.7 0.85 7.5 9.87 12.30 3680×2650×3050
SZ9-8000/35 9.84 42.8 0.75 7.5 12.55 15.30 4190×2930×3280
SZ9-10000/35 35
38.5
±3×2.5%
6.3
6.6
10.5
11


Ynd11
11.6 50.6 0.75 7.5 14.70 17.86 4620×3160×3400
SZ9-12500/35 13.7 60.0 0.70 8.0 17.35 20.05 4740×3200×3540
SZ9-16000/35 16.0 73.0 0.70 8.0 19.45 23.74 4810×3360×3790
SZ9-20000/35 18.9 88.3 0.70 8.0 27.50 34.95 4880×3540×4150
SZ9-25000/35 22.4 104.4 0.65 8.0 32.51 40.22 4920×3920×4200
SZ9-31500/35 26.6 125.3 0.65 8.0 37.73 45.53 5010×4270×4460
Ratedpower
(kVA)
Valtage Connction 9 loss(kW) 10 loss(kW) 11 loss(kW) No-load Loss(%) Impedence Voltage(%) Weight(t) Outline Dimension(mm) Guage
(mm)
H.V
(kV)
L.V
(kV)
No-Load Loss Load Loss No-Load Loss Load Loss No-Load Loss Load Loss Oil weight Untanking
weight
Total weight L B H
2000 35
38.5
±3×
2.5%
6.3
6.6
10.5
11
Yd11 2.88 20.25 2.59 19.24 2.30 19.24 0.80 6.5 1.9   7 3680 2050 2850 1070
2500 3.40 21.73 3.06 20.64 2.72 20.54 0.80 2.1   7.9 3780 2220 2890 1070
3150 4.04 26.01 3.64 24.71 3.23 24.71 0.72 7 2.4 7.5 8.5 3850 2310 2950 1070
4000 4.84 30.69 4.36 29.16 3.87 29.16 0.72 2.8 9.5 11 4120 2380 3150 1070
5000 5.80 36.00 5.22 34.2 4.64 34.2 0.68 3.1 10.5 12 4210 2510 3220 1070
6300 7.04 38.70 6.34 36.77 5.63 36.77 0.68 7.5 3.3 12.5 14.6 4320 3000 3290 1475
8000 YNd11 9.84 42.75 8.86 40.61 7.87 40.61 0.60 3.8 14 17.1 4500 3100 3680 1475
10000 11.60 50.58 10.44 48.05 9.28 48.05 0.60 4.3 17 20.1 4560 3500 3750 1475
12500 13.68 59.85 12.31 56.86 10.94 56.86 0.56 8 8.56 20 23 4650 3600 3830 1475
16000 16.46 74.02 14.81 70.32 13.17 70.32 0.54 9.5 23 27 5000 3800 3950 1475
20000 19.46 87.14 17.51 82.78 15.57 82.78 0.54 10 28.5 33 5200 4100 4000 1475
33kv 40000kVA Power Distribution Transformer33kv 40000kVA Power Distribution Transformer
Our Best Service For You
1. Pre sale service
A. Make technical solution
B. Send quotation, technical data sheet and drawing
C. Prepare power transmission plan, testing plan,and shipment plan
2. In sale service
A. Supervise the manufacturing schedule totally in accordance with the plan
B. Send photos to customer during every manufacturing process(hold point)
C. Inform the customer one week before testinng.
3. After sale service
A. Installation and commissioning, training the workers
B. Quick response within 12 hours any time
C. Provide 12 months gurantee period normally.

Thanks for choosing VILLE as your reliable partner and please trust both
of us will create a brilliant future!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
33kv 40000kVA Power Distribution Transformer pictures & photos
33kv 40000kVA Power Distribution Transformer
US $80,000-800,000 / Set
Min. Order: 1 Set
Gold Member Since 2007

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, IATF16949, ISO 14064, QC 080000, ANSI/ESD, ISO 29001, ISO 50001
Import & Export Mode
Have Own Export License
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram