Ship Transformer Marine Shore Power Isolation Transformer for All Boating and Marine Industry Manufacture

Product Details
Customization: Available
Application: Power, Electronic, Rectifier, Ship Power Supply
Phase: Single
Gold Member Since 2007

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, IATF16949, ISO 14064, QC 080000, ANSI/ESD, ISO 29001, ISO 50001
Import & Export Mode
Have Own Export License
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
  • Ship Transformer Marine Shore Power Isolation Transformer for All Boating and Marine Industry Manufacture
  • Ship Transformer Marine Shore Power Isolation Transformer for All Boating and Marine Industry Manufacture
  • Ship Transformer Marine Shore Power Isolation Transformer for All Boating and Marine Industry Manufacture
  • Ship Transformer Marine Shore Power Isolation Transformer for All Boating and Marine Industry Manufacture
  • Ship Transformer Marine Shore Power Isolation Transformer for All Boating and Marine Industry Manufacture
  • Ship Transformer Marine Shore Power Isolation Transformer for All Boating and Marine Industry Manufacture
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
Overview

Basic Info.

Model NO.
CSD
Core
Core-type Transformer
Cooling Method
Dry-type Transformer
Winding Type
Two-winding Transformer
Certification
CCS Ship Certification
Frequency Characteristics
Power Frequency
Shape of Core
OD
Brand
Ville
Energy Transmission
Two-Way Transmission
Output Power
Customerized
Transport Package
Wooden Cases
Specification
IEC Standard
Trademark
VILLE
Origin
Ningbo China
HS Code
8504231200
Production Capacity
50000 Sets/Year

Product Description

Product Description

The CSD ship transformer is designed specifically for marine applications, providing reliable and efficient power supply for various onboard systems.

The ambient temperature is -25 ~ 45 ° C, working frequency 50 ~ 60Hz;

The relative humidity of the air is not more than 95%;

Lighting, power distribution, or power grids used on ships, marine platforms and other places;

Safe and reliability requirements high

Normally two three-phase transformers: alternate.


Electric propulsion with gas turbine or diesel engine-driven power generation is used in hundreds of ships of various types and a large variety of configurations. 

Azimuthing thrusters and podded thrust units, propulsion configurations for transit, maneuvering, and station keeping have merged in several types of vessels in order to utilize installed thrust units for optimal transit, maneuvering, and dynamic positioning.

Demanding installation requirements, including reduced noise and vibration levels, limited space, a special water-cooled cooling system, and a high degree of security to avoid human risks, are some of the main reasons to choose VILLE transformers.
VILLE ENTERPRISE is a leading global manufacturer of  dry-type  and  liquid-filled distribution transformers  and  converter transformers  specifically designed to meet the requirements of marine applications.
VILLE ENTERPRISE transformers for marine applications are designed, manufactured, and approved by marine standards, including :
Ship Transformer Marine Shore Power Isolation Transformer for All Boating and Marine Industry Manufacture

Marine Transformer scope
• Rated power: up to 15 MVA
• Rated voltage: typically 6.6 and 11 kV;
others on demand
• Insulation system temperature: up to 155 ºC (class F), 180 ºC (class H)
• Cooling method for dry-type transformers: AN, ANAF, AFWF
• Cooling method for liquid-filled transformers: ONAN, ONAF, ONAN/ONA
• Fluids: mineral oil, synthetic ester (Midel 7131), natural ester
 

The CSD ship transformer is designed specifically for marine applications, providing reliable and efficient power supply for various onboard systems.

The ambient temperature is -25 ~ 45 ° C, working frequency 50 ~ 60Hz;

The relative humidity of the air is not more than 95%;

Lighting, power distribution, or power grids used on ships, marine platforms and other places;

Safe and reliability requirements high

Normally two three-phase transformers: alternate.

Detailed Photos

Ship Transformer Marine Shore Power Isolation Transformer for All Boating and Marine Industry Manufacture
Ship Transformer Marine Shore Power Isolation Transformer for All Boating and Marine Industry Manufacture

Product Parameters
Spec Capacity (kVA) Primary rated voltage(V) Voltage combination Link set label
50Hz 60Hz 50Hz 60Hz
CSD-5 5 400 450 400 230 115 400 230 115 Yy0 Yy11 Dd0
CSD-10 10
CSD-16 16
CSD-20 20
CSD-25 25
CSD-30 30
CSD-40 40
CSD-50 50
CSD-63 63
CSD-80 80
CSD-15000 15000
 

 


Ship Transformer Marine Shore Power Isolation Transformer for All Boating and Marine Industry Manufacture
Ship Transformer Marine Shore Power Isolation Transformer for All Boating and Marine Industry Manufacture
Ship Transformer Marine Shore Power Isolation Transformer for All Boating and Marine Industry ManufactureShip Transformer Marine Shore Power Isolation Transformer for All Boating and Marine Industry Manufacture
Ship Transformer Marine Shore Power Isolation Transformer for All Boating and Marine Industry Manufacture
Product structure characteristics:
Iron core: adopts High quality cold rolled oriented silicon steel sheet, All - diagonal multi - step ladder joint,tied up without
hole, clipped the Stainless steel drawplate with glass tape tightly.

Coil: winded with non - oxygen copper rod squeezed electromagnetic wire wrapped with high quality paper, insulate the
terminal by using company patent parts, multilayer brush stack end ring, to improve transformer short circuit withstand
capability. Adopts epoxy plates pressing device and increases the quantity of
press button and stud to improve the
mechanical strength of the coil.

Oil tank: corrugated tank, no lifting core structure, the mechanical strength is high and appearance is beautiful. We have
open top type,bell type and semi-bell type,etc. the oil tank has foundation which conforms to national rail distance standard
and provide trolley for installation according to any customer's civil working requirements. The low voltage outlet busbar
adopts company patent big current Groove type outlet terminal to avoid leakage.

Safety protection device: according to relevant state and industrial standard, transformer can be equipped with oil
conservator, gas relay, pressure relief valve, thermometer, oil sampling valve and various gas vent and oil filling valves.

Main executive standards:
GB/T 18494.1-2001----------- Industrial converter transformer
JB/T 8636-1997---------------- Power converter transformer
JB/DQ2113-1984-------------- Rectifying transformer for electrochemistry
GB1094-1996------------------ Power transformer
GB10230-1988---------------- On-load tap changer
GB/T311.1-1997--------------  Insulation coordination of HV electric transmission and transformation equipment
GB/T56011-1992-------------- Quality class of oil-immersed power transformer
GB/T6451-1999----------------Technical parameters and requirements of Three-phase oil-immersed power transformer

Please provide and confirm the following parameters when placing order:
  1. Primary voltage
  2. DC voltage(Udn)/ current(Udn)needed when rectifying.
  3. Rectifying method and phase number,
  4. Voltage regulating method
  5. Cooling method and power
 


Ship Transformer Marine Shore Power Isolation Transformer for All Boating and Marine Industry ManufactureShip Transformer Marine Shore Power Isolation Transformer for All Boating and Marine Industry ManufactureShip Transformer Marine Shore Power Isolation Transformer for All Boating and Marine Industry Manufacture
Ship Transformer Marine Shore Power Isolation Transformer for All Boating and Marine Industry Manufacture

Why VILLE ENTERPRISE?

  • A technology leader in transformers for marine applications
  • More than 30 years of experience in diesel-electric propulsion transformers
  • Transformers are suitable for operation and installation on-board any type of vessel
  • Marine application transformers are designed with high efficiency, incorporated safety, and superior operational reliability

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now