Customization: | Available |
---|---|
Application: | Power, Electronic, Rectifier, Ship Power Supply |
Phase: | Single |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The CSD ship transformer is designed specifically for marine applications, providing reliable and efficient power supply for various onboard systems.
The ambient temperature is -25 ~ 45 ° C, working frequency 50 ~ 60Hz;
The relative humidity of the air is not more than 95%;
Lighting, power distribution, or power grids used on ships, marine platforms and other places;
Safe and reliability requirements high
Normally two three-phase transformers: alternate.
Electric propulsion with gas turbine or diesel engine-driven power generation is used in hundreds of ships of various types and a large variety of configurations.
Azimuthing thrusters and podded thrust units, propulsion configurations for transit, maneuvering, and station keeping have merged in several types of vessels in order to utilize installed thrust units for optimal transit, maneuvering, and dynamic positioning.
Demanding installation requirements, including reduced noise and vibration levels, limited space, a special water-cooled cooling system, and a high degree of security to avoid human risks, are some of the main reasons to choose VILLE transformers.
VILLE ENTERPRISE is a leading global manufacturer of dry-type and liquid-filled distribution transformers and converter transformers specifically designed to meet the requirements of marine applications.
VILLE ENTERPRISE transformers for marine applications are designed, manufactured, and approved by marine standards, including :
Marine Transformer scope
• Rated power: up to 15 MVA
• Rated voltage: typically 6.6 and 11 kV;
others on demand
• Insulation system temperature: up to 155 ºC (class F), 180 ºC (class H)
• Cooling method for dry-type transformers: AN, ANAF, AFWF
• Cooling method for liquid-filled transformers: ONAN, ONAF, ONAN/ONA
• Fluids: mineral oil, synthetic ester (Midel 7131), natural ester
The CSD ship transformer is designed specifically for marine applications, providing reliable and efficient power supply for various onboard systems.
The ambient temperature is -25 ~ 45 ° C, working frequency 50 ~ 60Hz;
The relative humidity of the air is not more than 95%;
Lighting, power distribution, or power grids used on ships, marine platforms and other places;
Safe and reliability requirements high
Normally two three-phase transformers: alternate.
Spec | Capacity (kVA) | Primary rated voltage(V) | Voltage combination | Link set label | ||
50Hz | 60Hz | 50Hz | 60Hz | |||
CSD-5 | 5 | 400 | 450 | 400 230 115 | 400 230 115 | Yy0 Yy11 Dd0 |
CSD-10 | 10 | |||||
CSD-16 | 16 | |||||
CSD-20 | 20 | |||||
CSD-25 | 25 | |||||
CSD-30 | 30 | |||||
CSD-40 | 40 | |||||
CSD-50 | 50 | |||||
CSD-63 | 63 | |||||
CSD-80 | 80 | |||||
CSD-15000 | 15000 |