252kv Gis Zf -252 Sf6 Gas Insulated Metal Enclosed Switchgear 230kv Combination Switch

Product Details
Customization: Available
Function: Industry, Turn Switch, Dimmer Switch
Structure: Power Built-in Type
Gold Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, IATF16949, ISO 14064, QC 080000, ANSI/ESD, ISO 29001, ISO 50001
Import & Export Mode
Have Own Export License
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
  • 252kv Gis Zf -252 Sf6 Gas Insulated Metal Enclosed Switchgear 230kv Combination Switch
  • 252kv Gis Zf -252 Sf6 Gas Insulated Metal Enclosed Switchgear 230kv Combination Switch
  • 252kv Gis Zf -252 Sf6 Gas Insulated Metal Enclosed Switchgear 230kv Combination Switch
  • 252kv Gis Zf -252 Sf6 Gas Insulated Metal Enclosed Switchgear 230kv Combination Switch
  • 252kv Gis Zf -252 Sf6 Gas Insulated Metal Enclosed Switchgear 230kv Combination Switch
  • 252kv Gis Zf -252 Sf6 Gas Insulated Metal Enclosed Switchgear 230kv Combination Switch
Find Similar Products

Basic Info.

Model NO.
ZF10-126(L)/T3150-40
Usage
Disconnector, Change-over Switch, Control Switch
Contact Type
Type a Contact
Detection Method
Correlation Type
Pole
3
Rated Continuous Current
4000A
Number of Switch
Multi Control Switch
Brand
Ville
Certification
ISO9001, CE
Voltage Class
252kv
Standard
GB/IEC
Insulation
Gas
Transport Package
Wooden Case or as Per Requirement
Specification
IEC CE, ISO
Trademark
VILLE
Origin
Ningbo China
HS Code
85
Production Capacity
50000 Sets/Year

Product Description

252kv Gis Zf -252 Sf6 Gas Insulated Metal Enclosed Switchgear 230kv Combination Switch

Overview

ZF-252 Gas Insulated Metal-Enclosed Switchgear (hereinafter referred as GIS) is applicable for the electrical system with features of three phases
AC, 50Hz, and rated voltage of 252KV.
The GIS meets the relative requirements of national standard - GB7674-2008 and international standard IEC60517-1990.
All the components inside the GIS conform to the corresponding national standard.
ZF -252 SF6 gas insulated metal enclosed switchgear (simplified) GIS, used for three-phase AC 50Hz, 220kV power systems.The product adopts a
common phase three position isolation grounding switch structure and modular design It can meet various wiring methods.
Mainly used in power plants, substations, and large industrial and mining enterprises. Change to loss 
Open and close no-load, load and fault current, load conversion, and isolation line of the electrical system
Road, grounding protection, and measurement of electricity consumption, etc

Service and Installation Conditions
Installation site: Indoor/outdoor
Ambient temperature: -15~+40(indoor)/-35~+40(outdoor)
Altitude: 1000m (No limitation for special order)
Humidity:
Relative humidity at average per day (25): ≤ 95%
Relative humidity at average per month: ≤ 90%
Wind speed: ≤ 35m/s (wind pressure ≤ 700PA)
Sunshine intensity: 0.1W/cm(at wind velocity of 0.5m/s)
Icing thickness: 10mm
Seismic intensity:
Horizontal acceleration: ≤ 0.4G
Vertical acceleration: ≤ 0.2g
Symmetrical Creepage distance: 25mm/kV (pollution class III), 31mm/kV (class IV)
Keep the breaker away from places with combustible, explosive, corrosive materials and violent vibrations.

252kV Gas Insulated Switchgear(GIS) high voltage switchgear cabinet
 
Main features               
1.Spring mechanism/motor mechanism are adopted to avoid oil and gas to realize simple constrution, easy maintenance and realiable operation.

2.Enclosure is made of aluminium alloy to ensure light weight, low temperature-rise and strong anticorrosion.

3.Double sealing systems are adopted to guarantee high reliability in gas tightness and ensure minimum annual gas leakage.

4.GIS will be delivered as a whole without dismantle to reduce site installation and maintenance works.

5.Safety
Two measures are taken to ensure safety of operation personnel
Rupture disc is installed on every gas compartment to avoid explosion in over-pressure state.
Activating pressure of rupture disc on circuit breaker compartment: 1± 0.06MPa
Activating pressure of rupture disc on other compartments: 0.7± 0.04MPa
Destructive pressure that enclosure can withstand for circuit breaker compartment: 2.3MPa
Destructive pressure that enclosure can withstand for other compartments: 1.6MPa

6.Good insulating ability
Insulating barrier is made on production line imported form Hubers Company, Germany. The whole manufacturing process from mixture of fillings to
molding are finished in totally sealed and homoiothermal workshop to avoid occurance of air bubble inside insulating barrier. After being kept in
heating stove for more than 16 hours, insulating barrier will be conducted X-ray non-destructive test, mechanical test,power frequency withstand test
and partial discharge test, then it will be sealing packed and delivered to GIS assembly workshop.

7.Good conducting ability
Aluminum alloy conductors are coated with silver up to 24μm to reduce resistance as small as possible.

8.High current carrying performance
Copper with silver coat of strong adhesiveness is applied to ensure good current carrying performance and guarantee a long-term service.

9.View window
View windows are installed on GIS main components to observe service state inside GIS.

10. The circuit breaker is arranged horizontally, and the arc extinguishing chamber adopts a single break double action structure. The self energy arc extinguishing principle is equipped with a low-power spring operating mechanism, which effectively reduces mechanical stress, has high reliability, and has a mechanical life of 10000 times.

12. Adopting a three position isolation grounding switch structure, mechanical interlocking between isolation and grounding effectively avoids misoperation, with high reliability and a mechanical lifespan of 10000 times.

13. The three station isolation grounding switch and main busbar adopt a three-phase common box structure. The reduction of SF6 gas sealing and bonding surfaces reduces the probability of gas leakage; The three position isolation grounding switch has a simple structure and excellent corrosion resistance due to the absence of complex external connecting rods and fittings.

14. SF6 gas has a low rated pressure. Except for circuit breakers, all other gas chambers have a rated gas pressure of 0.4MPa, greatly reducing the amount of SF6 gas used and mitigating the greenhouse effect.
 
252kv Gis Zf -252 Sf6 Gas Insulated Metal Enclosed Switchgear 230kv Combination Switch.
252kv Gis Zf -252 Sf6 Gas Insulated Metal Enclosed Switchgear 230kv Combination Switch
252kv Gis Zf -252 Sf6 Gas Insulated Metal Enclosed Switchgear 230kv Combination Switch252kv Gis Zf -252 Sf6 Gas Insulated Metal Enclosed Switchgear 230kv Combination Switch252kv Gis Zf -252 Sf6 Gas Insulated Metal Enclosed Switchgear 230kv Combination Switch252kv Gis Zf -252 Sf6 Gas Insulated Metal Enclosed Switchgear 230kv Combination Switch 252kv Gis Zf -252 Sf6 Gas Insulated Metal Enclosed Switchgear 230kv Combination Switch
Thanks for choosing VILLE as your reliable partner and please trust both of us
will create a brilliant future!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier