Phase: Three
Core: Core-type Transformer
Cooling Method: Oil-immersed Type Transformer
Frequency Characteristics: Power Frequency
Max Rated Current: 200A 350A
Connection Method: Y, D
Customization:
Gold Member Since 2007

Suppliers with verified business licenses

Rating: 5.0/5

Basic Info.

Model NO.
SV
Rated Voltage
35kv or 66kv
No of Contact
The Thin Contacts Are 10 or 14
No of Working Position
It Could Reach 19 or 27 Positions.
No of The Middle Position
in The Middle Part There Are 0, 1, 3
Voltage Regulating Method
Positive and Negative Voltage
Transport Package
Wooden Cases
Specification
IEC CE, ISO
Trademark
VILLE
Origin
Ningbo
HS Code
85
Production Capacity
50000 Sets

Product Description

on-Load Tap Changer for Transformer Load Break Switch Tap Changer


The structure of SV on-load tap-changer

Compared with other products, we made some improvements as follows:

1. Change the selector

At present, the domestic products still use the old foreign structure, i. E., the movable contact makes connection
with the fixed contact. This structure has a large torque. Our company switched over to the traditional docking
structure with good contacts and small torque. The insulation bracket is made from three isolated wall with a
high-to-ground withstand voltage.

2. Under flange improvement

The under-flange s made of engineering plastics and lifted by four screws. While in the accidents, the increased
pressure often damage the under-flange (it occurs at home and abroad ). Therefore, our company strengthens
the prone-to-crack place to ensue good strength.

3. Correct arc principle

Some domestic manufacturers apply with slide between are contact and rotating pole. When the arc contact
leaves from the fixed contact, the current will breaks, and the current passes through arc contact to the rotating
rod. As the gap between the two can only connect by the arc, the rotating rod will burn off and the gap will get
larger, resulting in the broken of the rotating poles, thus accidents arise. We considered of this and take
appropriate measures

4. Correct resistance installation

Products of the same kind at home and abroad have no outer resistance baffle. Resistance will be scattered in
accidents. Under the effect f elasticity, it collapses which cause the tapping short circuit and threaten the safety
of the transformer. We add one baffle at the outer layer of resistances as a preventive measure, enhancing the
reliability.

Type designation
Voltage-regulating method: W- Positive- Negative voltage- Regulating G- - Thickness regulating
No. Of the middle position: In the middle part there are 0, 1 and 3.
No. Of working position: It could reach 19 or 27 positions.
No. Of contact: The thin contacts are 10 or 14.
Voltage grade (kV): Rated insulation level: 35 kV or 66 kV.
Connection method: Y- Neutral connection, D- Other connection

Technical parameters:
Max. Rated current (A): 200A, 350A
No. Of phase: III - Three-phase I- Single-phase

E. G. SV III 350 Y - 66 - 10 193 W
SV series switch, three-phase, maximum rated current 350 A, neutral connect, voltage at 66 kV, 10 contacts for
thin-regulating, 19 working positions, 3 middle-position, which conversion selector, positive-negative regulating.
Type SV350 SV200
Max.rated current (A) 350 200
No. Of phases
 
1 3 3 1 3 3
Connect Method
 
_ Y D _ Y D
Short-current test current (kA) Heat stabilization (3 seconds. )
Act-stabilization (peak value )
5
12.5
4
10
Voltage between grades (V) Spot 10
Spot 12
Spot 14
1500
1400
1000
1500
1400
1000

REFERENCE TRANSFORMER:
on-Load Tap Changer for Transformer Load Break Switch Tap Changer
on-Load Tap Changer for Transformer Load Break Switch Tap Changer
on-Load Tap Changer for Transformer Load Break Switch Tap Changer

Company Profile:
on-Load Tap Changer for Transformer Load Break Switch Tap Changer
on-Load Tap Changer for Transformer Load Break Switch Tap Changer

Our Best Service For You
1. Pre sale service
a. make technical solution
b. send quotation, technical data sheet and drawing
c. prepare power transmission plan, testing plan and shipment plan
2. In sale service
a. supervise the manufacturing schedule totally in accordance with the plan
b. send photos to customer during every manufacturing process(hold point)
c. inform the customer one week before testing.
3. After sale service
a. installation and commissioning, training the workers
b. quick response within 12 hours any time
c. provide 12 months guarantee period normally.

FAQ For You
1. Q: What is your delivery time ?
A:  Depend on the type of transformer.
2. Q: What is your payment term?
A:  30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it.
3. Q: What kind of standard you follow?
A:  IEC, ANSI, CSA, GB, etc
4. Q: What kind of supporting documentation you can provide normally
A:  Quotation, outline drawing, manufacturing plan, quality control plan
testing plan, financial report, type test report(KEMA, CESI),reference list, etc
5. Q: What is your normal warranty period?
A:  12 months after transformer operation.
6. Q: Can u do installation and commission in user's site?
A:  Yes, we can send our installation team to user's country for service.
7. Q: Do you have any experience in this kind of transformer?
A:  Yes, we can provide reference list for check.

Our advantages:
Quality Assurance
--From the very beginning, VILLE ensures quality in every step to achieve the best quality.
 Experience Sharing
--With more than 30 years' experience in power industry, VILLE brings you an optimized solution.
 Global Service
--Wherever you are, VILLE global network will support and provide you with value.
 Quick Response
--In response to your needs without delay, VILLE  knows the value of your time.

Thanks for choosing VILLE as your reliable partner and
please trust both of us will create a brilliant future!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2007

Suppliers with verified business licenses

Rating: 5.0/5
Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, IATF16949, ISO 14064, QC 080000, ANSI/ESD, ISO 29001, ISO 50001
Import & Export Mode
Have Own Export License
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram