Tyd500/ 3-0.005h 500kv Voltage Transformer

Product Details
Customization: Available
Application: Electronic, Instrument, Position Sensor, Audio
Type: Current Transformer
Gold Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, IATF16949, ISO 14064, QC 080000, ANSI/ESD, ISO 29001, ISO 50001
Import & Export Mode
Have Own Export License
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
  • Tyd500/ 3-0.005h 500kv Voltage Transformer
  • Tyd500/ 3-0.005h 500kv Voltage Transformer
  • Tyd500/ 3-0.005h 500kv Voltage Transformer
  • Tyd500/ 3-0.005h 500kv Voltage Transformer
  • Tyd500/ 3-0.005h 500kv Voltage Transformer
  • Tyd500/ 3-0.005h 500kv Voltage Transformer
Find Similar Products

Basic Info.

Model NO.
TYD500/ 3-0.005H
Phase
Single
Operation Condition
Outdoor
Usage
Measurement
Winding Form
Multilayer Honeycomb Type
Insulating Medium
Epoxy Resin
Installation
Strut Type
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Electromagnetic Type
Transport Package
Wooden Case for Accessories
Specification
IEC Standard
Trademark
VILLE
Origin
Ningbo China
HS Code
85
Production Capacity
50, 000 Set/Year

Product Description

Introduction:
Anti-resonant voltage transformer, with 4 windings, nominal voltage 500 kV, from transformation ratio 500: √3 / 0.1: √3 / 0.1: √3 / 0.1kV, with
contact terminals for connecting three wires in phase. Rated voltage of the secondary windings: Winding No. 1 for power supply of relay
protection and automation circuits (connection according to the "star with zero" scheme) - 100 /: √3V Winding No. 2 for power supply of
metering and electrical metering circuits (connection according to the "star with zero" scheme) - 100 /: √3V Winding No. 3 additional
(connection according to the scheme  "Open delta") - 100V Accuracy class 0.2 / 0.2 / 3

Technical indicators 4.1. Rated secondary load of the protection winding (10 PR) - 20VA. The rated maximum current ratio for the protection
winding (the ratio of the max short-circuit current to the rated primary current of the CT, at which the CT error is less than 10% at a given
secondary load) is 30. The intrinsic resistance of the current transformer is not more than 36 ohms. The rated secondary load of the
measurement and metering windings is 30VA. - Wind head - V = 29m / s. - Ice-covered area - II (10 mm) - Minimum temperature - 25 0
FROM - Maximum temperature - +50 0 FROM - Seismic - 7 points on the MSK-64 scale - Equipment insulation - II * (specific creepage
distance 2.25 cm / kV) in accordance with GOST 9920-89
Tyd500/ 3-0.005h 500kv Voltage Transformer
Tyd500/ 3-0.005h 500kv Voltage Transformer
Tyd500/ 3-0.005h 500kv Voltage Transformer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier