• Rfm1-2400-25s Reactive Power Compensator Capacitor 2400kvar 1000V 25kHz
  • Rfm1-2400-25s Reactive Power Compensator Capacitor 2400kvar 1000V 25kHz
  • Rfm1-2400-25s Reactive Power Compensator Capacitor 2400kvar 1000V 25kHz
  • Rfm1-2400-25s Reactive Power Compensator Capacitor 2400kvar 1000V 25kHz

Rfm1-2400-25s Reactive Power Compensator Capacitor 2400kvar 1000V 25kHz

Type: Heating
Application: Power, High Voltage
Packaging Type: Enclosure
Capacitance: Customized
Structure: Fixed Capacitor
Manufacturing Material: Customized
Customization:
Gold Member Since 2007

Suppliers with verified business licenses

Rating: 5.0/5

Basic Info.

Model NO.
RFM1-2400-25S
Electrolyte
Customized
Usage
Adjust Power Factor
Tuning
Customized
Filter
Customized
Voltage
4kv
Frequency
50Hz
Transport Package
Standard Export Wooden Case
Specification
As per drawing
Trademark
VILLE
Origin
China
HS Code
84
Production Capacity
50000 Sets/Year

Product Description

Introduction to Product

The capacitors are applicable to the controlled or adjustable AC voltage system with the nominal voltage not more than 4KV and the
frequency of 50KHz and below. It is specially used to improve the power factor or circuit characteristics of induction heating, melting, stirring
or casting devices, and similar applications.


Feature:

1 The capacitor is mainly composed of shell, connecting rod and core.
2 The shell is made of aluminum plate by bending welding. The capacitor core is installed in the shell, which is filled with insulating oil with
   excellent electrical performance. The supports for installation and lifting are welded at both ends of the shell, and the wiring guide rod sealed
   with silicone rubber and supported by porcelain sleeve is installed on the shell cover.

3 The capacitor core is composed of several dozens of components, which are assembled as a whole through insulation pad and splint
   according to the design method, and the cooling water pipe is directly welded with the element plate.


Technical specification:

Rfm1-2400-25s Reactive Power Compensator Capacitor 2400kvar 1000V 25kHz

1 product standards:GB / t3984.1 power capacitors for induction heating installations Part 1 general principles (equivalent to iec60110.1
   power capacitors for induction heating installations Part 1 General).

2 capacitor terminals (between poles) can withstand 2.0un power frequency test voltage for 10s.
3 for capacitors whose terminals are insulated from the shell, the power frequency test voltage of 2.15un and minimum 2000V shall be
   applied between the terminals and the shell for 10s.

4 capacitance deviation range: no more than - 5% ~ + 10% of rated value.
5 under power frequency rated voltage, the loss tangent (TG δ) of capacitor shall not be greater than 0.0008
6 overload: the capacitor can operate continuously under the rated voltage and 1.15 times of the rated current, and can operate for no more
   than 12 hours every 24 hours under 1.05 times of the rated voltage.

7 main technical data and overall dimensions of capacitor (see attached table and attached figure 1-9).
Rfm1-2400-25s Reactive Power Compensator Capacitor 2400kvar 1000V 25kHz
Rfm1-2400-25s Reactive Power Compensator Capacitor 2400kvar 1000V 25kHz
Rfm1-2400-25s Reactive Power Compensator Capacitor 2400kvar 1000V 25kHz
Rfm1-2400-25s Reactive Power Compensator Capacitor 2400kvar 1000V 25kHz
Rfm1-2400-25s Reactive Power Compensator Capacitor 2400kvar 1000V 25kHz
Rfm1-2400-25s Reactive Power Compensator Capacitor 2400kvar 1000V 25kHz
Rfm1-2400-25s Reactive Power Compensator Capacitor 2400kvar 1000V 25kHz
Rfm1-2400-25s Reactive Power Compensator Capacitor 2400kvar 1000V 25kHz

Technical Data for TYPE: RFM1-2400-25S
CAPACITOR 2400kvar 25kHz - 2713785
CAPACITOR 2400kvar - 1000V - 25kHz
WITH 20 EXTRA BRASS NUTS M12 / SW24
THICKNESS: 8mm

TECHNICAL DATA:
NOMINAL VOLTAGE: Un = 1000VAC
NOMINAL CAPACITY: Cnom = 15.28UF
NOMINAL CURRENT: Inom = 2400AAC
NOMINAL REACTIF POWER: Qnom = 2400kvar
NOMINAL FREQUENCY: Fnom = 25kHz

THE NOMINAL CAPACITY IS DIVIDED OVER 10 TAPS:
TAPS 0-1: C = 1.92UF - Q = 300kvar
TAPS 0-2: C = 1.92UF - Q = 300kvar
TAPS 0-3: C = 1.92UF - Q = 300kvar
TAPS 0-4: C = 1.92UF - Q = 300kvar
TAPS 0-5: C = 1.92UF - Q = 300kvar
TAPS 0-6: C = 1.92UF - Q = 300kvar
TAPS 0-7: C = 1.92UF - Q = 300kvar
TAPS 0-8: C = 0.96UF - Q = 150kvar
TAPS 0-9: C = 0.64UF - Q = 100kvar
TAPS 0-10: C = 0.32UF - Q = 50kvar

TEMPERATURE RANGE: -20 ° C to +50 °
C CAPACITY TOLERANCE: - 5% to + 10%
Maximum allowable voltage: 105% of nominal voltage
Maximum permissible current: 115% of the rated current
TANG DELTA losses: <0.05% at 50 Hz, 20DEG. C
WEIGHTS: 19 kg
Case: ALUMINUM
CASE: Alive
Protection: IP00
CHILLED WATER:
MINIMUM WATER FLOW: 6 l / min COMPLIANCE IEC60110-1

Rfm1-2400-25s Reactive Power Compensator Capacitor 2400kvar 1000V 25kHzRfm1-2400-25s Reactive Power Compensator Capacitor 2400kvar 1000V 25kHz

Using environment:

1 the altitude of the installation site shall not exceed 1000m.
2 indoor air temperature range - 40 ~ + 45 ºC.
3 the residual voltage during re energization shall not exceed 10% of the rated voltage.
4 the inlet pressure of cooling water shall not exceed 0.4MPa, the inlet water temperature shall not exceed 30 ºC, the cooling water flow
   shall not be lower than 6L / min, the cooling water shall be soft water without impurities, and the pH value shall be 6-9.


Our Performance:
1. Pre sale service
a. make technical solution
b. send quotation, technical data sheet and drawing
c. prepare power transmission plan, testing plan,and shipment plan
2. In sale service
a. supervise the manufacturing schedule totally in accordance with the plan
b. send photos to customer during every manufacturing process(hold point)
c. inform the customer one week before testinng.
3. After sale service
a. installation and commissioning, training the workers
b. quick response within 12 hours any time
c. provide 12 months gurantee period normally.

FAQ For You
1. Q: What is your delivery time ?
A:  Depend on the type of transformer.
2. Q: What is your payment term?
A:  30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it.
3. Q: What kind of starndard you follow?
A:  IEC, ANSI, CSA, GB, etc
4. Q: What kind of supporting documentation you can provide normally
A:  Quotation,outline drawing,manufacturing plan, quality control plan
testing plan, financial report, type test report(KEMA, CESI),reference list,etc
5. Q: What is your normal wanrranty period?
A:  12 months after transformer operation.
6. Q: Can u do installation and commissioningin user's site?
A:  Yes, we can send our installation team to user's country for service.
7. Q: Do you have any experience in this kind of transformer?
A:  Yes, we can provide reference list for check.
8. Q: Are you manufacturer or trading company?
A:  Manufacturer and Trading company.

Quality Assurance
--From the very beginning, VILLE ensures quality in every step to achieve the best quality.
 Experience Sharing
--With more than 30 years' experience in power industry, VILLE brings you an optimized solution.
 Global Service
--Wherever you are, VILLE global network will support and provide you with value.
 Quick Response
--In response to your needs without delay, VILLE  knows the value of your time.

Ville Electric Company will keep up with the century, the epoch,

Sincerely look forward to your cooperation and win-win!

Create brilliant!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2007

Suppliers with verified business licenses

Rating: 5.0/5
Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, IATF16949, ISO 14064, QC 080000, ANSI/ESD, ISO 29001, ISO 50001
Import & Export Mode
Have Own Export License
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram