125kVA 10kv Oil Immersed Three Phase Amorphous Alloy Transformer/Distribution Transformer

Product Details
Customization: Available
Application: Power, Electronic, Instrument, Rectifier
Phase: Three
Still deciding? Get samples of US$ 2500/Piece
Request Sample
Gold Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, IATF16949, ISO 14064, QC 080000, ANSI/ESD, ISO 29001, ISO 50001
Import & Export Mode
Have Own Export License
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
  • 125kVA 10kv Oil Immersed Three Phase Amorphous Alloy Transformer/Distribution Transformer
  • 125kVA 10kv Oil Immersed Three Phase Amorphous Alloy Transformer/Distribution Transformer
  • 125kVA 10kv Oil Immersed Three Phase Amorphous Alloy Transformer/Distribution Transformer
  • 125kVA 10kv Oil Immersed Three Phase Amorphous Alloy Transformer/Distribution Transformer
  • 125kVA 10kv Oil Immersed Three Phase Amorphous Alloy Transformer/Distribution Transformer
Find Similar Products

Basic Info.

Model NO.
125kva
Core
Core-type Transformer
Cooling Method
Oil-immersed Type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001-2000, ISO9001
Usage
Distribution Transformer
Frequency Characteristics
High Frequency
Shape of Core
Ring
Brand
Ville
Test
Type Test Report
Test Certification
Iei Transformer Test
Transport Package
Wooden Cases
Specification
IEC CE, ISO
Trademark
VILLE
Origin
Ningbo China
HS Code
8504220000
Production Capacity
3000/Year

Product Description

General:
 load regulating power transformer is developed and produced according to the requirement of the market. It
can be widely used in urban & rural, industrial & agricultural power network, which has a great significance for
energy-saving and environment protection. The lamination method of this product's iron core is ladder form,
instead of the traditional iron core lamination technology, which improves the magnetic circuit distribution inside
the iron core. It can be seen as a revolution of transformer iron core manufacturing. Compared with the
traditional, the no-load loss, no-load current and noise of the new one decrease 20% respectively, and load
loss decreases 10%. The new product applies CAD, with advance design, reasonable structure, and excellent
materials. Each index complies with the standards of GB1094-1996 "Power Transformer" GB/T6451-1999
"Technical Parameters and Requirements of Three-phase Oil-immersed Type Power Transformer". Now its level
is the leading position of our country.

Features:
High reliability, advanced level of performance, economic indicators and reasonable;
Using phase-shaped core of three joints, curing paint brushing the surface to reduce wear and tear and noise;
Winding structure of a new oil road design is reasonable, with the new insulation to improve the mechanical
strength and the ability to engage in short-circuit;
Tank forms, beautiful, generous.

Range of application:
It can be widely used in urban power network as well as petrochemical, metallurgical, textile and humid,
inaccessible enterprises, and mining.

Technical parameters:
Rated Capacity (KVA):125
Voltage Raatio (kv): HV:10±2x5%   LV:0.4
Connection Symbol:Dyn11
No-load Loss (W):85
Full-load Loss (W):1890
No-load Current (%):0.8
Impedance (%):4
Weight (KG):Oil Weight:160    Gross Weight:720
Outline Dimension (mm):LxWxH=1010x690x1080
Gauge(mm):550x550
 
TYPE Capacity KVA Load
Loss
Load Negative consu-mption Load
Current
Impedance voltage Dimensions Weight KG
A B C D E F
S9-M-30/10 30 130 600 2.1 4.0 770 635 1000 14 400 400 310
S9-M-50/10 50 170 870 2.0 4.0 1100 660 1030 14 400 450 395
S9-M-63/10 63 200 1040 1.9 4.0 1130 670 1100 14 400 450 450
S9-M-80/10 80 210 1250 1.8 4.0 1140 675 1110 14 400 450 490
S9-M-100/10 100 290 1500 1.6 4.0 1185 690 1130 14 400 450 560
S9-M-125/10 125 340 1800 1.5 4.0 1205 710 1180 19 550 550 670
S9-M-160/10 160 400 2200 1.4 4.0 1255 720 1200 19 550 550 780
S9-M-200/10 200 480 2600 1.3 4.0 1295 740 1215 19 550 550 875
S9-M-250/10 250 560 3050 1.2 4.0 1340 755 1260 19 550 650 1115
S9-M-315/10 315 670 3650 1.1 4.0 1400 770 1320 19 550 650 1280
S9-M-400/10 400 800 4300 1.0 4.0 1500 860 1400 19 660 750 1495
S9-M-500/10 500 960 5150 1.0 4.0 1575 895 1430 19 660 750 1740
S9-M-630/10 630 1200 6200 0.9 4.5 1660 930 1545 19 660 850 2110
S9-M-800/10 800 1400 7500 0.8 4.5 1830 1070 1590 19 820 850 2625
S9-M-1000/10 1000 1700 10300 0.7 4.5 1935 1175 1685 19 820 850 2860
S9-M-1250/10 1250 1950 12000 0.6 4.5 1960 1170 1730 19 820 850 3330
S9-M-1600/10 1600 2400 14500 0.6 4.5 2050 1220 1810 19 820 900 3765
S9-M-2000/10 2000 2520 17820 0.5 4.5 2030 1215 1940 19 820 900 4530
S9-2500/10 2500 2970 23000 0.5 5.5 2280 2070 2415 19 820 1070 7050

125kVA 10kv Oil Immersed Three Phase Amorphous Alloy Transformer/Distribution Transformer

125kVA 10kv Oil Immersed Three Phase Amorphous Alloy Transformer/Distribution Transformer

125kVA 10kv Oil Immersed Three Phase Amorphous Alloy Transformer/Distribution Transformer
125kVA 10kv Oil Immersed Three Phase Amorphous Alloy Transformer/Distribution Transformer

Work shop
125kVA 10kv Oil Immersed Three Phase Amorphous Alloy Transformer/Distribution Transformer
125kVA 10kv Oil Immersed Three Phase Amorphous Alloy Transformer/Distribution Transformer
125kVA 10kv Oil Immersed Three Phase Amorphous Alloy Transformer/Distribution Transformer
Our Performance:
1. Pre sale service
a. make technical solution
b. send quotation, technical data sheet and drawing
c. prepare power transmission plan, testing plan,and shipment plan
2. In sale service
a. supervise the manufacturing schedule totally in accordance with the plan
b. send photos to customer during every manufacturing process(hold point)
c. inform the customer one week before testinng.
3. After sale service
a. installation and commissioning, training the workers
b. quick response within 12 hours any time
c. provide 12 months gurantee period normally.

FAQ For You

1. Q: What is your delivery time ?
A:  Depend on the type of transformer.
2. Q: What is your payment term?
A:  30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it.
3. Q: What kind of starndard you follow?
A:  IEC, ANSI, CSA, GB, etc
4. Q: What kind of supporting documentation you can provide normally
A:  Quotation,outline drawing,manufacturing plan, quality control plan
testing plan, financial report, type test report(KEMA, CESI),reference list,etc
5. Q: What is your normal wanrranty period?
A:  12 months after transformer operation.
6. Q: Can u do installation and commissioningin user's site?
A:  Yes, we can send our installation team to user's country for service.
7. Q: Do you have any experience in this kind of transformer?
A:  Yes, we can provide reference list for check.
8. Q: Are you manufacturer or trading company?
A:  Manufacturer and Trading company.

Ville Electric Company will keep up with the century, the epoch,

Sincerely look forward to your cooperation and win-win!

Create brilliant!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier