Czbt1-132kv 132kv/11.5KV movable Mobile power transofrmer substation
Outdoor,dust and water proof (132/11.5)kv,25mva Mobile substation according to IEC standard .
The Mobile substation consists of two trailer(A&B).
Trailer (A) Carries the following equipments:
* Three pcs lighting arrester of (120kv,10ka) .
*3-phase,two-pole,vertical break(145kv,630A,31.5KA/1SEC).disconnected switch with earth switch at transformer side.
*3-phase,vacuum circuit breaker(145kv,630a,31.5KA/1SEC).with spring operating mechanism.
*One,3-phase(132kv/11.5kv)25mva YND11 oil immersed power transformer with (17) steps on load tap changer(OLTC) at high voltage side with regulatio( ±10% of 132kv).
*One pcs lighting arrester of (75kv,10ka)at neutral point of 25mva power transformer.
*One,3-phase,75kva,11.5kv/380v-220v,znyn1,auxiliary&earthing transformer with neutral current 300A/10SEC.
*Safety fence.
*All current transformers for 132kv side and neutral point are bushing types.
Trailer (B) Carry the following equipments:
One cabinet dust and water proof contain the control panel,protection panel,A,C distribution board,metering and energy board and equipped with suitable air condition.
One cabinet contain the 12kv,air-insulation metal-enclosed switchgear the switchgear consists of (one panel for 12kv voltage transformer with surge arrester,one panel for 12kv incoming feeder,five panels for out going feeders).
One Cabinet contain 110V,D.C system( charger,battery and D.C distribution board) with suitable ventilation
Technical requirements for electrical system:
132kv system
*Highest system voltage 145kv
*Impulse with stand voltage
For Bushing 650KV
For winding 550KV
For Neutral 350KV
*Power frequency withstand test voltage(for 1min)
For Bushing 275kv
For winding 230kv
For Neutral 140KV
*Rated breaking capacity 31.5ka
Creeage distance ≥ 25mm/KV
11.5KV System
*Highest system voltage 12kv
Impulse with stand voltage
For Bushing 75kv
for winding 75kv
for neutral 75kv
*power frequency withstand test voltage(for 1 min).
For bushing 28kv
for winding 28kv
for neutral 28kv
*Rated breaking capacity 31.5KA
Creepage distance ≥25mm/KV
Technical feature:
1. Faster recovery of power
>>The prefabricated mobile substation is applied to fully or partial replace the conventional substation and resume the power supply in case
of emergency.
2.Flexible solution
>>Help an area which suffers shortage of power supply capacity in heavy load season or period. Use as the temporary substation in areas
with booming power demands that exceed the existing electric power capability,to ease the tension of power supply.
3. Temporary solution
>>Work as a temporary substation in areas of permanent substation suspended due to the capital shortage or other kind of reason.
4. Reliable solution
>>The prefabricated mobile substation is the flexible and reliable way for transportation with the complete equipment. It also saves
investment in various aspects, concerning the land requisition, civil construction,equipment installation etc, which improves the reliability
of power supply for the system.
5. Higher efficiency
>>The prefabricated mobile substation provides with all the functions that a conventional substation has, as well as easy installation and
quick into the service. It could be into operation at once on site after the connection of input and output cable only.
Our Advantage:
1.Various special requirement from customer or typical specification .
2.Competitive price (Real Factory).
3.Excellent quality control and faster feedback .
4.Good service and after sales.
5.In time delivery.
6. Manufacturing after drawings approved.
7.OEM is acceptable.We can change the design as client's requirements.
Technical parameters
Main transformer capacity ( MVA): 5, 7.5, 10, 15, 20, 25, 31.5;
HV side Swith gear rated voltage ( KV ): 33, 66, 77, 110, 132, 138:
Rated current (A): 1250A, 2000A;
Rated short circuit break current (KA): 25, 31.5, 40;
LV side Switch gear rated voltage (KV): 6.6, 11, 13.8, 22, 33:
Rated current (A): 1250, 2000, 2500, 3150;
Rated short circuit break current (KA): 25, 31.5, 40
Our workshop
Our international sales team
Our Services
1. |
Pre sale service |
a. |
make technical solution |
b. |
send quotation, technical data sheet and drawing |
c. |
prepare power transmission plan, testing plan,and shipment plan |
2. |
In sale service |
a. |
supervise the manufacturing schedule totally in accordance with the plan |
b. |
send photos to customer during every manufacturing process(hold point) |
c. |
inform the customer one week before testinng. |
3. |
After sale service |
a. |
installation and commissioning, training the workers |
b. |
quick response within 12 hours any time |
c. |
provide 12 months gurantee period normally. |
Order Instructions
When you choose our company product, please offer following data:
Transformer model:
Rated capacity: kVA
Phase:Three-phase
Single-phase
Frequency:50HZ
60HZ
Rated voltage ( H.V. / L.V. ):
Tapping range: ± × %
Insulation level: LI AC / LI AC kv
Veotor group:Dyn11
Yyno
Other
Short-circuit Impedance: %
Cooling method:ONAN
ONAF
Tapping method:OLTC
OCTC
Other
Single line diagram for mobile substation
Other requirement:
Notes:
We also can design special products according to customer's particular requirements.
The final dimension is subject to outline drawing.