Basic Info.

Model NO.
WTZ-288
Display
Pointer
Material
Bimetallic
Hygrometer Type
Dry and Wet Bulb Thermometer
After-Sales Service
on-Line
Warranty
1 Year
Indicative Accuracy
1.5(About Measuring Range)
Extra Pipe Size (M)
3, 5, 10, 16
Contact Form
Lower and Upper Limit
Contact Capacity
10va(Without Reactance)
Control Estate Explain
Refer Chart 1
Transport Package
Wooden Cases
Specification
IEC CE, ISO
Trademark
VILLE INDUSTRY
Origin
Ningbo China
HS Code
8
Production Capacity
50000 Sets/Year

Product Description

General:
The Model WTZ-288 Electric Contact Thermometer is designed to take measurement and control of the
temperature ranging from -20ºC to 120ºC in non-corrosive site within a distance of 16 m.
With the application of working principle of pressure-type thermometer, the WTZ-288 is featured by being
simple structure, easy to use and at moderate price.

Contact thermometer is suitable to within 16 m, Measuring range is (+20º C~+120º C) with no cauterization
occasion in measuring and controlling. Model WTZ-288 series contact thermometer adopts the elements of
pressure thermometer, it has a handy structure, use simple and convenient, the low price and so on.

Main Technical Parameters:
1, The temperature dimension and measuring rage:
Dimension range: -20~+60 0~100 20~120
Measuring range: 20~60 40~100 60~120
2, Indicative accuracy: 1.5 grade
3, Trail length(m): 3, 5, 10, 16. (According to the clients request, If it isn't show clearly the length, according to
5m)

 Recommended added circuit
The power rating of each electric contact in the WTZ-288 is only 10VA without reactance, so users have to
resolve the problem of the contact power magnification. For your convenience, we would rather recommend you
a power magnification circuit with anti-oscillation and arc extinction (refer to figure 3).
Circuit Feature: Once the lower limit contact closes, the lower limit circuit gets self-locked. Only dose the upper
limit contact close, the ower limit circuit unlocks. Therefore, the electric contacts are well protected.
Control mode Measured temperature Functional mode of contacts
Lower and upper 
limits
Below lower limit 1-2
3-2
open
close
Between lower and
upper limits
1-2
3-2
open
open
Above upperlimit 1-2
3-2
close
open
 
Main Technical Parameters
1.Temperature Mark & Measuring Range(ºC):
Mark Range -20~+60 0~100 20~120
Measuring Range 20~60 40~100 60~120
2.Indicative Accuracy:1.5(About Measuring Range)
3.Extra Pipe size (m): 3,5,10,16.(If not mention when order, we will make
 the pipe 5m long)
4.Electric Contact capability:
Contact form:lower and upper limit;
Contact capacity:10VA(without reactance)
Connecting Diagram: refer figure 2;
Control estate explain: refer chart 1

Recommended added circuit
The power rating of each electric contact in the WTZ-288 is only 10VA without reactance, so users have to
resolve the problem of the contact power magnification. For your convenience, we would rather recommend you
a power magnification circuit with anti-oscillation and arc extinction (refer to figure 3).
Circuit Feature: Once the lower limit contact closes, the lower limit circuit gets self-locked. Only dose the upper
limit contact close, the ower limit circuit unlocks. Therefore, the electric contacts are well -protected.
Electric Contact Thermometer Transformer Winding ThermometerElectric Contact Thermometer Transformer Winding ThermometerElectric Contact Thermometer Transformer Winding Thermometer
Our advantages:
Quality Assurance
--From the very beginning, VILLE ensures quality in every step to achieve the best quality.
 Experience Sharing
--With more than 30 years' experience in power industry, VILLE brings you an optimized solution.
 Global Service
--Wherever you are, VILLE global network will support and provide you with value.
 Quick Response
--In response to your needs without delay, VILLE  knows the value of your time.

Thanks for choosing VILLE as your reliable partner and
please trust both of us will create a brilliant future!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier